Buy a full case and the price per unit drops automaticallyRequest a sample
AccountCart0
All ContainersBottlesJarsCaps & ClosuresPumps & SprayersTubs & PailsJugsDroppersTinsTubesAccessoriesSeals & LinersCansBags & PouchesVialsLabels & DecorationBuckets & PailsDrumsBoxes & MailersBottling Tools
Industries
Learn

How to burn test a candle

Updated

On this page10

To burn test a candle, you burn cured test candles in sessions of up to four hours, record the flame, melt pool, smoke and vessel every hour, let them cool fully, and repeat until each candle is finished. You test several wick sizes side by side, and you judge each one against written pass and fail limits rather than by eye. This page gives the full procedure, the limits one retailer publishes for the candles it buys (Kohl's Test Protocol 100-Z), where candle suppliers' own testing advice differs, and how to handle tealights, votives, coated and multi-wick candles.

Before the first light

Get these right before you light anything, because a mistake here spoils the whole test.

Cure the candles for the time your wax maker gives. Supplier figures differ. CandleScience's burn test instructions ask for a candle cured at least 24 hours [1]. The manufacturer's instructions for Golden Brands GW 464 soy wax say to let candles sit undisturbed 48 hours before test burning [2]. Northwood says at least 24 hours, and 2 weeks for the most accurate results [3]. Supplies for Candles in the UK lists cure times by wax, from 24 to 48 hours for paraffin to 10 to 14 days for its ProSoy and KeraSoy, and warns that testing before full cure gives misleading results [4]. Follow your own wax's data sheet; how long candles need to cure explains why these figures differ.

Number every test candle. Write a number on the base or the jar and record it against the wax, wax lot, fragrance and load, dye, wick, vessel, fill, pour temperatures and pour date. Supplies for Candles recommends exactly this, with each candle given an identifiable number recorded on the sheet [5]. Keeping burn test records lists the fields.

Make the candle you will sell. Same vessel, same fill line, same label position, same lid. A test candle with no label tells you nothing about whether the label scorches.

Set up the surface. Kohl's protocol has its laboratory burn candles on a flat table covered in aluminum foil, with votives in a holder supplied by the laboratory [6]. At home, use a level, heat-resistant surface out of drafts. The National Candle Association tells consumers to keep candles away from open windows, fans and air vents, at least 12 inches from anything that can burn, and at least 3 inches from other burning candles [7]. For side-by-side tests, CandleScience spaces candles three to six inches (7.6 to 15.2 cm) apart [1] and Supplies for Candles leaves at least a 6 inch gap [5]. Wider spacing is the safer choice when candles are of different sizes, because a hot neighbor changes the result.

Have the tools ready: a ruler in inches and millimeters, a timer, a thermometer for the vessel surface (how hot the jar gets), a skewer for melt pool depth, a snuffer, a camera and the burn test record sheet.

Which wicks, and how many candles

Start from a wick chart and test the chart's suggestion with the sizes on either side. Supplies for Candles says to always test at least three sizes: your estimate, one size down and one size up [4]. How to size a wick shows how to read a chart and pick the candidate.

None of these suppliers' instructions sets how many candles of each wick to burn, and the Kohl's laboratory runs its burning tests on a single sample [6]. A retailer's lab is checking a finished, already developed product; you are choosing a wick. One candle tells you about that candle, including any off-center wick or bad pour. A repeat of the same build tells you about the design. If two candles of the same build disagree, you have learned that your pouring is not yet consistent, which is worth knowing before you make a hundred.

Change one thing at a time. The GW 464 instructions say to "test for one variable at a time when trouble shooting to isolate the cause" [2], and CandleScience says not to switch wicks partway through a test [1].

The burn test, step by step

  1. Trim the wick. CandleScience trims to 1/4 inch (6 mm) before every lighting [1]; the National Candle Association gives consumers the same 1/4 inch [7]. Kohl's requires at least 1/4 inch of exposed wick for lighting [6]. Supplies for Candles trims to 5 mm [5]. Record the length, and use the same length on every candle in the test.
  2. Light and start the clock. Note the time and the room temperature.
  3. Record every hour. At minimum: flame height, melt pool width and depth, any smoke, the wick (straight, curling, mushrooming), the vessel surface temperature, and anything unusual. Kohl's records its readings hourly [6], as do CandleScience [1] and Supplies for Candles [5]. Photograph each candle from above and from the side.
  4. Stay in the room. Never leave a burning candle unattended [7]. If you must leave, put the candles out and count that session as short.
  5. Extinguish at the end of the session. For most candles Kohl's burns sessions of 4 hours [6]. CandleScience says always to extinguish after four hours [1], and Supplies for Candles lists burning longer than 4 hours as a common mistake [4]. Northwood uses 2 to 4 hours [3]. Use 4 hours unless you are testing something the Kohl's protocol treats differently (see the special cases below).
  6. Watch the afterglow. Time how long the wick tip glows and smokes after the flame is out. Kohl's limit is 30 seconds [6].
  7. Let the candle cool completely. CandleScience allows at least five hours of cooling before the next cycle [1]. Do not move a candle while the wax is liquid [7].
  8. Repeat until the candle is finished. Kohl's laboratory burns only during working hours, up to 8 hours a working day with hourly readings [6], which means two sessions a day at most. Keep going to the end of the candle (see the next section).
  9. Stop at once for any safety failure listed in the table below. Do not relight that candle; record what happened and photograph it.

Do not judge a wick on its first burn. CandleScience says not to draw conclusions until at least the fourth burn cycle, and that wax left on the wall should melt down by the third or fourth cycle [1].

The pass and fail limits one retailer publishes

The table below is Kohl's Test Protocol 100-Z for candles, revised February 2025, the current revision [6]. Its candle limits are unchanged from the previous revision, 100-Y (February 2023), and both are built on the 2017 edition of ASTM F2417 [6]. It is one retailer's buyer protocol for the candles it buys, and F2417 is the industry's voluntary fire safety standard. Kohl's wrote it for its own suppliers; the ASTM text is a separate document, no law adopts the Kohl's figures, and nothing requires a maker selling elsewhere to meet them. It is used here because it is the most complete set of published numbers a maker can test against. The current F2417 edition is F2417-26 [8], and the six ASTM candle standards are described on the ASTM standards page.

What is checkedKohl's requirement [6]Where it is covered
Flame height3 inches maximum for most candles; 3.75 inches for religious or ceremonial candles; outdoor candles reported as data onlyMeasuring flame height
AfterglowWick tip goes out within 30 secondsMeasuring flame height
Visual smoke (indoor candles)Each hourly reading recorded as intermittent or continuous; intermittent no more than 20 percent of total burn hours, continuous no more than 10 percentMeasuring soot and smoke
Container temperatureExternal surface no more than 140°F (60°C) for metal, 175°F (79°C) for ceramic or glass; report minimum, maximum and averageHow hot the jar gets
OverflowMolten wax must not escape and reach the burning surfaceReading the melt pool
Container integrityThe container of a filled candle, including a tealight cup, must not crack or breakCracked or broken candle jars
Secondary ignitionNone (exceptions for religious or ceremonial candles and non-freestanding birthday candles)Secondary ignition
Flame impingementA freestanding candle's flame must not impinge on its supporting surfacePillar problems
StabilityFreestanding and filled candles, tealights included, must not tip on a 10.0° incline (tolerance -0°/+0.5°); asymmetrical candles are tested at any rotation; freestanding candles must not tip on a level surface while burningCandles that tip or lean
Burning timeMust meet the claimed burn time with no shortfall (-0 percent); claimed and actual time reported in hours and minutesKeeping burn test records
AbnormalitiesReport anything that could cause damage or a hazard, such as glitter popping or small rocks explodingSecondary ignition
WickAt least 1/4 inch exposed; no metal core allowedCandle wick types

Kohl's has tightened and loosened figures over time. Its revision history records the container temperature limit changing from 160°F to 175°F, the afterglow limit from 15 to 30 seconds, and the referenced F2417 edition moving from -04 through -09, -11 and -16 to -17 [6]. A different buyer may set different numbers, so ask any retailer for its own protocol before you test for it.

Where suppliers' own test advice differs

Candle suppliers publish test instructions that agree on the method and differ on the numbers. These are each supplier's guidance for its own customers, not standards.

QuestionCandleScience [1]Supplies for Candles [4] [5]Northwood [3]This page follows
Session lengthUp to 4 hours, then at least 5 hours cooling4 hours, then cool fully2 to 4 hours4 hours, which matches the Kohl's protocol [6]
Typical flameAbout 1 inch (2.5 cm); up to 2 inches (5 cm) normalAround 10 to 15 mmAbout 1 inchRecord the actual height; judge safety against a written limit such as Kohl's 3 inches
Melt poolWithin 1/4 inch (6 mm) of the edge at 3 to 4 hours; 1/4 to 1/2 inch (6 to 13 mm) deepFull pool by hour 3 to 41/4 to 3/4 inch deep when fully meltedSee reading the melt pool
When to stopWhen 1/4 inch (6 mm) of wax remainsTest to the bottom of the candleNot statedSee the next section

The Supplies for Candles flame figure (10 to 15 mm) is well below CandleScience's 1 inch. Neither is a limit. They describe what each supplier considers a healthy flame in the waxes it sells, and they show why your records should hold your own measured figures.

Testing to the end of the candle

End of use is one of the four failures the ASTM fire safety standard was written to address [9], and it is the part of a candle that a quick test never reaches. The flame is closest to the base, the vessel is hottest, and any weakness in the glass, the wick tab or the wick centering shows up there.

The National Candle Association tells consumers to stop burning a candle when 1/2 inch of wax remains [7]. CandleScience's test instructions burn until 1/4 inch (6 mm) remains [1]. This page follows both, for different purposes: your test candles go past the consumer stop point so you know how the last stretch behaves, and the instructions you give customers use the National Candle Association's 1/2 inch (burn instructions to give customers). Record the vessel temperature and flame height with extra care in those final sessions.

Candles that are tested differently

  • Tealights. Kohl's burns tealights and tealight ensembles to the end of their useful life in one continuous burn [6], because that is how they are used.
  • Votives. Kohl's burns votives in a holder [6]. Test yours in the holder you sell or recommend; see votives and tealights.
  • Gel candles are burned for 8 hours by Kohl's [6]. Gel candles are not covered here beyond the note on flash point.
  • Coated candles. For candles with a coating, Kohl's uses 24 samples and checks flame height, secondary ignition, flame impingement and tipping [6].
  • Plastic containers. Kohl's burns 10 unused empty containers; their total burn time must be 300 seconds or less, and no single container may burn more than 30 seconds or be completely consumed [6].
  • Multi-wick candles. The pools merge, the flames heat one another, and the vessel runs hotter. When a candle needs two or three wicks has a checklist for testing them.

Stop the burn if you see any of these

What you seeWhy it matters
A flame anywhere other than the wickSecondary ignition, one of the four leading fire causes [9]
A flame climbing past 3 inches, or splitting into more than one flamePast the Kohl's flame limit [6]
A crack, a chip or a sound from the glassContainer integrity failure [6]
Wax running over the rimOverflow failure [6]
The flame touching the vessel wallWick drift; glass heated in one spot
Continuous smokeOver the Kohl's smoke limits if it persists [6]

Put the candle out with a snuffer, not water, which can make hot wax splatter [7]. Leave it where it is until it is fully cool.

Choosing the wick after the last session

Compare the wick sizes candle by candle against your limits. If one passed every check from first light to the end, that is your wick for this exact build. If none did, when to change the wick size tells you which way to move, and reading the melt pool explains what each pool was telling you along the way.

References

  1. CandleScience, How to Conduct a Burn Test, undated, read October 22, 2026. https://candlescience.com/learning/how-to-conduct-a-burn-test/
  2. Voyageur Soap & Candle, Golden Brands GW 464 Soy Container Candle Wax (product page with manufacturer's instructions), undated, read October 22, 2026. https://www.voyageursoapandcandle.com/Golden_Brands_464_Soy_Wax_p/20264.htm
  3. Northwood, How to Test Candles (help center article), undated, read October 22, 2026. https://northwood-knowledge.groovehq.com/help/how-to-test-candles
  4. Supplies for Candles, The Complete Guide to Wick Testing: What Every Candle Maker Needs to Know, published February 26, 2026, modified September 2, 2026. https://www.suppliesforcandles.co.uk/the-complete-guide-to-wick-testing-what-every-candle-maker-needs-to-know/
  5. Supplies for Candles, How to Take Test Burn Notes, published July 30, 2021, modified September 2, 2026. https://suppliesforcandles.co.uk/candle-college/how-to-take-test-burn-notes
  6. Kohl's, Private Brands Performance Claims Test Protocols 100, Protocol 100-Z: Candle (including freestanding, taper, tealight, votive, filled and novelty candles), revised February 2025 (current revision; candle limits unchanged from 100-Y, February 2023), read October 22, 2026. https://link.kohls.com/content/dam/klink/100-Z-CANDLE.pdf
  7. National Candle Association, Candle Safety Tips, modified August 12, 2025. https://candles.org/candle-safety/
  8. ASTM International, ASTM F2417-26 Standard Specification for Fire Safety for Candles (store scope page), last updated July 3, 2026. https://store.astm.org/f2417-26.html
  9. Doug Clauson, Increasing Candle Safety, ASTM Standardization News, March/April 2013 (posted July 26, 2016). https://www.astm.org/news/increasing-candle-safety-ma13