How do you measure whether a candle soots?

Updated

On this page7

You measure soot in a burn test the way retail buyers do: by watching for visible smoke at every hourly reading, classifying it, and checking what the flame has deposited on the vessel and the wick. Kohl's, in the protocol it uses for candles it buys, records each hour's smoke as intermittent or continuous and fails an indoor candle if intermittent readings pass 20 percent of the burn hours or continuous readings pass 10 percent. A laboratory method for collecting soot also exists, ASTM F2326, but it is a comparison tool for product development rather than a pass or fail test. This page covers both, plus the checks you can do at home.

What soot is, in a candle test

Soot is unburned carbon. A flame makes it when it is given more fuel than it can burn cleanly, which is why most sooting traces back to an oversized wick, a mushroomed wick tip, a draft that makes the flame flicker, or something other than the wick feeding the flame. The visible plume above a smoking candle and the black film it leaves on the glass are the parts you can see and record. What else is in candle smoke, and what the research says about indoor air, is covered on what the research says about candle smoke. Fixing a sooting candle is on stopping a candle from sooting. This page is about measuring it.

The retailer method: classify the smoke every hour

Kohl's Test Protocol 100-Z (revised February 2025, with the same limits as 100-Y of February 2023) applies a visual smoke check to indoor candles. Smoke is assessed hourly and recorded as "Intermittent" or "Continuous," and the limits are a share of all the hours the candle burned [1]:

Kohl's smoke classification [1]Limit, as a share of total burn hours
IntermittentNo more than 20 percent
ContinuousNo more than 10 percent

This is one retailer's buyer requirement. It has no legal force and is separate from the ASTM standards. Kohl's does not define the two terms in the protocol [1], so you need your own written definitions and must apply them the same way every time. These work, and are this page's suggestion rather than Kohl's wording:

  • None: no smoke visible above the flame during the reading.
  • Intermittent: smoke appears in puffs or wisps, for example when the flame flickers, then clears.
  • Continuous: a steady thread or plume of smoke rises for the whole time you watch.

Watch for a fixed time at each reading (a full minute is reasonable) against a plain, dark background so a thin plume shows up.

Working the limit for a real candle

Suppose a candle burns for 44 hours in total, in sessions of 4 hours, with a reading every hour. That gives 44 readings. Under the Kohl's limits [1]:

  • Intermittent readings may be no more than 20 percent of 44, which is 8.8, so 8 readings at most.
  • Continuous readings may be no more than 10 percent of 44, which is 4.4, so 4 readings at most.

The arithmetic matters because smoke is rarely spread evenly. A candle that is clean for 30 hours and smokes steadily for the last 6 fails on continuous smoke, even though it looked perfect for most of its life. That is one more reason to burn test candles to the end.

What ASTM F2326 is, and what it is not

ASTM F2326 is the Standard Test Method for Collection and Analysis of Visible Emissions from Candles as They Burn, one of the six voluntary candle standards the Consumer Product Safety Commission lists [2]. The current edition is F2326-04(2021) [3]. According to ASTM's published scope, it covers the collection and analysis of visible emissions from indoor-use candles as they burn, and it is meant for comparing relative smoke and burn behavior while a candle is being designed and formulated [4].

Three points in that published summary matter to a maker [4]:

  • It is not a pass or fail test. ASTM says the method sets no standard level for visible smoke. It ranks candle designs against each other.
  • It may not suit every candle. ASTM notes it may not be suitable for multi-wick candles, tapers or floating candles.
  • Wick trim matters. In developing the method, test candles' wicks were trimmed to 6 to 7 mm (1/4 inch) before each burn cycle, and ASTM recommends a consistent trimming protocol so results can be compared.

The procedure itself is in the purchased standard and is not described here. Most makers will never run F2326; a laboratory may, if a buyer asks for it (see do you need a lab to test your candles?). Its value to you is the principle it rests on: compare one build against another under identical conditions, with the same trim, and treat soot as a relative measure.

Checks you can do at home

These do not replace the hourly smoke classification; they add physical evidence to it.

CheckWhenWhat to recordWhat it suggests
Smoke at each readingEvery hourNone, intermittent or continuous, using your written definitionsThe basis for the Kohl's style percentages [1]
Plume when the flame flickersEvery hourWhether puffs come only with flickerDraft or an unsteady flame; check the room first
Black deposit on the inside of the rimAfter each session, once coolLocation and extent; a photoCandleScience treats heavy soot on the container edge as a sign to wick down [5]
Black deposit concentrated on one sideAfter each sessionWhich sideWick leaning or off center, or a draft from that direction
Carbon on the wick tipEvery hourSize of any mushroom cap; whether it drops into the poolCandleScience lists mushrooming that tips into the wax or drops carbon into the pool as a sign to wick down [5]
Carbon debris in the poolAfter each sessionSpecks or chunks in the cooled waxDebris can feed a second flame; see secondary ignition
Wipe testAfter the last sessionWipe the inside rim with a white tissue and photograph it beside the tissue from another buildA simple side-by-side comparison in the spirit of F2326; it is not a measurement

Keep the trim the same for every candle in the test, as the F2326 summary advises [4]. CandleScience trims to 1/4 inch (6 mm) before every lighting and says mushrooming is much worse if that step is skipped [5]; the National Candle Association gives consumers the same 1/4 inch trim to prevent high flames and soot [6].

Reading the soot record

Soot almost never stands alone in the record. A candle that soots usually also shows a tall flame, a mushroomed wick, a deep pool or a hot jar at the same readings. Supplies for Candles lists soot appearing on the vessel among its reasons to wick down, together with an excessively tall flame and heavy mushrooming [7]. Look at those columns together before you decide what to change.

Soot patternMost likely meaning
Soot with a tall flame and a deep poolWick too large for this build
Soot only with flickerDraft; retest in still air before changing the wick
Soot that grows each session, with a growing carbon capWick series or size mushrooms in this wax and load; see wick mushrooming
Soot only in the last sessionsFlame low in the vessel with poor airflow, or end of use heating
Soot that started after a change of fragrance, load or dyeThe change, not the wick; test the change on its own

Fixing a candle whose record shows smoke

If your record shows smoke past your limits, stopping a candle from sooting lists the causes in order of likelihood and what to change, and when to change the wick size helps you choose the next wick to test.

References

  1. Kohl's, Private Brands Performance Claims Test Protocols 100, Protocol 100-Z: Candle (including freestanding, taper, tealight, votive, filled and novelty candles), revised February 2025 (current revision; candle limits unchanged from 100-Y, February 2023), read October 22, 2026. https://link.kohls.com/content/dam/klink/100-Z-CANDLE.pdf
  2. U.S. Consumer Product Safety Commission, Candles Business Guidance, undated, read October 22, 2026. https://www.cpsc.gov/Business--Manufacturing/Business-Education/Business-Guidance/Candles
  3. ANSI Webstore, ASTM F2326-04(2021) Standard Test Method for Collection and Analysis of Visible Emissions from Candles as They Burn (listing marked most recent), read October 22, 2026. https://webstore.ansi.org/standards/astm/astmf2326042021
  4. ASTM International, ASTM F2326-04(2009) store page (scope and significance; lists F2326-04(2021) as the active edition), last updated February 27, 2015. https://store.astm.org/f2326-04r09.html
  5. CandleScience, How to Conduct a Burn Test, undated, read October 22, 2026. https://candlescience.com/learning/how-to-conduct-a-burn-test/
  6. National Candle Association, Candle Safety Tips, modified August 12, 2025. https://candles.org/candle-safety/
  7. Supplies for Candles, The Complete Guide to Wick Testing: What Every Candle Maker Needs to Know, published February 26, 2026, modified September 2, 2026. https://www.suppliesforcandles.co.uk/the-complete-guide-to-wick-testing-what-every-candle-maker-needs-to-know/