What should a burn test record include, and how long should you keep it?
Updated
On this page8
A burn test record needs two parts: a header that identifies exactly what was burned (wax and lot, fragrance and load, dye, wick, vessel, fill, pour temperatures, cure time, pour date) and an hourly log of what happened (flame height, melt pool width and depth, smoke, wick condition, vessel temperature, anything unusual), with photographs and a numbered candle tied to a batch record. No federal rule sets how long to keep burn test records, so keep them for as long as any candle made to that specification could still be in a customer's home; if you use metal-cored wicks, the records behind your certificate have a five-year federal minimum. This page lists the fields, shows how to link tests to batches, and explains what a retailer's lab reports.
The header: what was burned
Fill this in before you light the candle. If you cannot fill in a field, you cannot repeat the candle, and a test of a candle you cannot repeat proves nothing about the next one.
| Field | Why it is there |
|---|---|
| Test candle number | Supplies for Candles recommends labeling each test candle with an identifiable number and recording it on the sheet [1] |
| Date poured and date of first burn | Gives the cure time actually used |
| Wax: product name, supplier, lot number | A different wax, or a reformulated one, is a different candle |
| Wax weight | Supplies for Candles lists wax used and weight [1]; the fill weight per jar comes from your test pour (how full to fill a candle jar) |
| Fragrance oil: name, supplier, lot; load as a percent and as a weight | CandleScience records fragrance oil and fragrance load [2]; say whether the percent is of the wax or of the whole candle (how much fragrance oil to use) |
| Dye: type and amount | CandleScience and Supplies for Candles both record it [1] [2] |
| Additives, if any | Each is a retest variable |
| Wick: supplier, series, size, tab, priming | CandleScience records wick choice [2] |
| Vessel: supplier, product, diameter, material, any coating | CandleScience records container type and diameter [2] |
| Fill height | Changes where the flame sits late in the candle's life |
| Melt, fragrance addition and pour temperatures | Supplies for Candles lists all three [1] |
| Cure time before the test | Supplies for Candles records how long the candle cured [1] |
| Surface appearance before lighting | Supplies for Candles suggests noting frosting, wet spots, jump lines, sweating, rough surfaces, sinkholes or air bubbles [1] |
| Room conditions | Temperature and any draft sources; these explain odd results later |
| Limits being tested to | For example, the Kohl's figures, named and dated (how to burn test a candle) |
The hourly log: what happened
Supplies for Candles suggests hourly intervals as best [1], and CandleScience [2], Northwood [3] and the Kohl's laboratory protocol [4] all work hourly.
| Column | How to record it |
|---|---|
| Session and hour | Session 1, hour 1, and so on, with clock time |
| Wick length at lighting | The trim you used, in inches or millimeters |
| Flame height | Measured against a ruler behind the flame; see measuring flame height |
| Flame behavior | Steady, flickering, flaring, more than one flame |
| Melt pool width | Distance from the wall, or "full" |
| Melt pool depth | Measured with a skewer; see reading the melt pool |
| Smoke | None, intermittent or continuous, using your written definitions; see measuring soot and smoke |
| Wick condition | Straight, curling, leaning, carbon cap size |
| Vessel temperature | Each measuring point; see how hot the jar gets |
| Scent | Hot throw at the doorway, if you are testing it |
| Notes and photo number | Anything unusual, and the file name of the photo |
At the end of each session add: afterglow in seconds, the time the candle was put out, and wall wax after cooling. At the end of the test add: total burn time in hours and minutes, wax remaining, the session in which any limit was exceeded, and a pass or fail verdict against each limit.
Photographs
Take one from directly above and one from the side at each hourly reading, with the test candle number visible in the frame. Name the files with the candle number, session and hour so they sort in order. Photos settle arguments your notes cannot: whether the pool really reached the wall, how big the carbon cap was, where soot built up on the glass.
What a retailer's lab report contains
If you sell to a large retailer, its laboratory, not you, produces the report that matters to the buyer, and your records are how you know before you submit that you will pass. Kohl's Test Protocol 100-Z (February 2025, with the same limits as the earlier 100-Y) shows what one buyer's report includes [4]:
- Hourly readings for burning characteristics, with abnormalities reported.
- Each hour's smoke recorded as intermittent or continuous, against limits of 20 percent and 10 percent of total burn hours.
- Flame height against a 3 inch maximum for most candles.
- Afterglow, which must end within 30 seconds.
- Container temperature as a minimum, maximum and average, against 140°F (60°C) for metal and 175°F (79°C) for glass or ceramic.
- Claimed and actual burn time in hours and minutes, with no shortfall allowed against the claim.
- Overflow, container integrity, secondary ignition, flame impingement and stability results.
Those are Kohl's figures for the candles it buys, built on ASTM F2417-17; they are one buyer's rules and no legal standard [4]. If your records use the same fields, your own tests and a buyer's lab results can be compared line by line. What larger retailers require covers the rest of what a buyer asks for.
One field deserves special care: burn time. If your label or listing states a burn time, Kohl's treats the claim as a requirement the candle must meet [4]. Record total burn time on every test, and never claim a figure your records do not support.
Linking tests to batch records
A burn test is about a specification. A batch record is about a production run. The link between them is what lets you answer "was this candle tested?" for any candle you have sold.
- Give every specification a code (for example, the scent name plus a version number) and write it on the burn test header.
- When the test passes, record the date, the test candle numbers and the verdict against that specification code.
- Put the specification code on every batch record, along with the wax, fragrance and wick lot numbers used. The batch record template has the fields.
- When a confirmation burn is run on a new lot, record it against the same code, with the new lot numbers (what has to be retested).
- If anything in the specification changes, it gets a new version number and a new full test.
How long to keep them
CPSC's candle business guidance sets no retention period for burn test records [5], and none of the supplier or retailer documents cited here sets one. The decision is yours, and the sound basis for it is the life of the product: a candle can sit in a cupboard for years before it is burned, and a question about it can come long after the sale. Keep the test records for every specification for as long as candles made to it could still be in use, and keep them together with the batch records that cite them.
Records for metal-cored wicks are a different matter. CPSC requires a General Certificate of Conformity (GCC) for metal-cored wicks and candles that use them, and none for nonmetal-cored wicks [5]; under 16 CFR 1110.17, the certificate and the test results it is based on must be kept for at least five years from the date the certificate was created [6]. The lead test behind a GCC is a different record from a burn test; if you file them together, keep the whole file on the five-year schedule. What the certificate must contain is covered on certificates of conformity for candles. The full set of records a candle business keeps, including complaints, is on records a candle business keeps.
Paper or digital
Either works if it is complete, dated and backed up. A printed sheet beside the candles is easier to fill in with wax on your hands; a spreadsheet is easier to search when a customer calls. A workable routine uses both: paper during the burn, typed up the same day with the photos attached. The burn test record sheet has every field on this page in printable and digital form.
Top picks
Top containers for candles
4 oz · 58-400 · Glass · Amber · 2.6 in
16 oz · 89-400 · Glass
9 oz · 70-400 · Glass
4 oz · 58-400 · Glass · Clear
4 oz · 58-400 · Glass · Amber · 2.7 in
6 oz · 63-400 · Glass
4 oz · Steel
12 oz · 63-400 · Glass
References
- Supplies for Candles, How to Take Test Burn Notes, published July 30, 2021, modified September 2, 2026. https://suppliesforcandles.co.uk/candle-college/how-to-take-test-burn-notes
- CandleScience, How to Conduct a Burn Test, undated, read October 22, 2026. https://candlescience.com/learning/how-to-conduct-a-burn-test/
- Northwood, How to Test Candles (help center article), undated, read October 22, 2026. https://northwood-knowledge.groovehq.com/help/how-to-test-candles
- Kohl's, Private Brands Performance Claims Test Protocols 100, Protocol 100-Z: Candle (including freestanding, taper, tealight, votive, filled and novelty candles), revised February 2025 (current revision; candle limits unchanged from 100-Y, February 2023), read October 22, 2026. https://link.kohls.com/content/dam/klink/100-Z-CANDLE.pdf
- U.S. Consumer Product Safety Commission, Candles Business Guidance, undated, read October 22, 2026. https://www.cpsc.gov/Business--Manufacturing/Business-Education/Business-Guidance/Candles
- 16 CFR 1110.17, Recordkeeping requirements, as revised at 90 FR 1843, January 8, 2025 (eCFR reproduction, CustomsMobile, checked for updates October 22, 2026), read October 22, 2026. https://www.customsmobile.com/regulations/16/1110.17