If you manufacture, package, label or hold a dietary supplement, 21 CFR Part 111 expects written specifications, a master manufacturing record for each product, a batch record for every batch, and logs for equipment, reserve samples, training, distribution, complaints and returns, each signed or initialed when the work is done [1]. This page holds fourteen blank templates, one for each of those records, laid out as tables you can copy onto paper or into your own forms. Each one names the Part 111 section it answers and links to the page that explains the rule. The complaint template also carries the adverse event record that 21 U.S.C. 379aa-1 requires.
The fourteen records at a glance
| # | Template | Part 111 sections it answers [1] | Explained on |
|---|
| 1 | Component specification | 111.70(b), 111.75(a) | Writing specifications |
| 2 | Finished product specification | 111.70(e), (g); 111.75(c) | Writing specifications |
| 3 | Supplier qualification record | 111.75(a)(2)(ii)(A) to (E) | Qualifying a supplier |
| 4 | Identity test record | 111.75(a)(1), 111.75(h)(1) and (h)(2) | Identity testing for herbs |
| 5 | Master manufacturing record (MMR) | 111.205, 111.210, 111.123(a)(1) | The master manufacturing record |
| 6 | Batch production record (BPR) | 111.255, 111.260 | The batch production record |
| 7 | In-process weight check sheet | 111.75(b), 111.260(g), (h) | Fill weight checks during a batch |
| 8 | Quality control review and release | 111.113, 111.123(a)(8), 111.127(h), 111.140(b)(2) | Quality control when you work alone |
| 9 | Equipment cleaning and calibration log | 111.25, 111.27, 111.35(b) | Cleaning and calibrating equipment |
| 10 | Reserve sample log | 111.83(b), 111.465 | Records and reserve samples |
| 11 | Training record | 111.12(b), 111.14(b) | Training, hygiene and illness |
| 12 | Complaint log, with adverse event record | 111.560, 111.570; 21 U.S.C. 379aa-1 | Handling product complaints and serious adverse event reporting |
| 13 | Returned product log | 111.503 to 111.535 | Returned product |
| 14 | Distribution record | 111.410(d), 111.415(f), 111.475(b)(2) | Holding and distributing product |
Each subpart also asks for written procedures, the "how we do it" documents behind these records; Part 111 at a glance lists them subpart by subpart. These templates are the "what we did" side.
How to set up the file
- Number and version every form. A specification or master record carries a document number, a version and the date quality control approved it. Keep every superseded version, because batches made under it still point to it.
- Write at the time. Part 111 asks for many entries to be documented "at the time of performance" (111.260(j) to (n), 111.570(b)(2)) [1]. Fill the form in as the step happens, in ink or in a system that records when each entry was made.
- Sign in the role. Quality control entries need the date and the "Signature of the person performing the review, approval, or rejection" (111.140(b)(2)) [1]. If you are both maker and quality control, sign quality control entries as quality control, as a separate act; why that matters is on quality control when you work alone.
- Paper or electronic. Records may be originals, true copies or electronic records, and "All electronic records must comply with part 11 of this chapter" (111.605(c)) [1]. A form filled in by hand and signed is an original.
- Blanks are entries. Write "None" or "n/a" rather than leaving a line empty. FDA's warning letters have cited master records with required elements left out, as what FDA cites at small supplement makers shows.
Before production: specifications and suppliers
1. Component specification
One sheet per component: each dietary ingredient, the shell, each excipient. Answers 111.70(b) and 111.75(a) [1][2].
| Field | Entry |
|---|
| Component name; specification number and version | |
| Type: dietary ingredient, or other component | |
| For a botanical: Latin binomial and plant part | |
| Approved supplier(s) | |
| Quality control approval: signature and date (111.105(a)) | |
| Attribute | Specification (limit) | Method or examination | Basis or reference | Checked by your own test, or a qualified supplier's certificate? |
|---|
| Identity | | | | Dietary ingredient: your own test or examination, every lot (111.75(a)(1)) |
| Purity | | | | |
| Strength | | | | |
| Composition | | | | |
| Lead | | | | |
| Arsenic | | | | |
| Cadmium | | | | |
| Mercury | | | | |
| Microbial limits | | | | |
| Moisture | | | | |
| Particle size | | | | |
| Allergen status and source | | | | |
| Storage conditions | | | | |
A supplier's certificate can stand in for your test only for components that are not dietary ingredients, and for specifications other than a dietary ingredient's identity, after the supplier is qualified under template 3 [2].
2. Finished product specification
One sheet per product. Answers 111.70(e) for identity, purity, strength, composition and contaminant limits, and 111.70(g) for the packaged and labeled product [1].
| Field | Entry |
|---|
| Product name; MMR number | |
| Specification number and version; quality control approval, signature and date | |
| Testing plan: every finished batch, or a sound statistical sampling plan (111.75(c)) | |
| Attribute | Specification | Method | Units needed per test |
|---|
| Identity of each dietary ingredient | | | |
| Strength: amount per serving of each declared ingredient | | | |
| Composition | | | |
| Contaminants: heavy metals | | | |
| Contaminants: microbial | | | |
| Appearance | | | |
| Average net fill and spread | | | |
| Disintegration, if adopted | | | |
| Packaged and labeled: count, label version, lot number and date legible, seal intact | | | |
| Units for one full set of tests | | | Total: |
| Reserve sample: at least twice the total (111.83(b)(4)) | | | Units: |
3. Supplier qualification record
One record per supplier and material. Answers the five conditions in 111.75(a)(2)(ii) [2].
| Condition | What to record | Entry |
|---|
| Scope | Material, and which specifications you will rely on the certificate for | |
| (A) Confirm the supplier's results | Your own or an independent lab's tests on supplier lots, compared side by side (table below) | |
| (B) Certificate content | Each certificate shows the test method, the limits and the actual results; reject "conforms" with no numbers | |
| (C) Documentation | Where the qualification file is kept | |
| (D) Periodic re-confirmation | Your written interval and the reason for it | |
| (E) Quality control approval | Signature and date | |
| Status | Qualified, suspended, re-qualified; dates and reasons | |
| Supplier lot | Attribute | Supplier's result | Your result | Lab and method | Within your agreement criteria? |
|---|
| | | | | |
4. Identity test record
One record per lot of each dietary ingredient. Answers 111.75(a)(1); the method must be appropriate and scientifically valid (111.75(h)(1)) and of a kind listed in 111.75(h)(2) [1][2]. The fields follow identity testing for herbs.
| Field | Entry |
|---|
| Component and specification number | |
| Supplier, supplier lot, your receiving lot | |
| Date received; date examined | |
| Sample: containers sampled, amount | |
| Method and procedure number | |
| Reference used (voucher, authenticated reference material) | |
| Observations, feature by feature against the specification | |
| Result: pass, fail or inconclusive (inconclusive is not a pass) | |
| Examined by; training record reference | |
| Retained portion: where kept | |
| Quality control review and disposition: released or rejected, signature, date | |
Making a batch
5. Master manufacturing record
One per formulation and batch size. Answers 111.205 and each paragraph of 111.210; quality control approves it and every change (111.123(a)(1)) [1].
| Field | Entry |
|---|
| MMR number, version; quality control approval, signature and date | |
| (a) Product name; strength of each dietary ingredient; batch size | |
| (e) Intentional overage of any dietary ingredient, and why ("None" if none) | |
| (f) Theoretical yield at each point; acceptable range that triggers an investigation, ___ to ___ percent | |
| (g) Packaging description; representative label attached (version) | |
| (h)(4) Special notations and precautions | |
| (h)(5) Corrective action plan when a specification is not met | |
| (b) Component | Specification number | (c) Amount for this batch size | (d) Declared amount per unit |
|---|
| | | |
| Step | (h)(3) Instruction | (h)(1) Specification at this step | (h)(2) Sampling and test procedure | Verification by a second person? |
|---|
| | | | |
For manual operations, 111.210(h)(3)(ii) calls for one person to weigh or measure and another to verify, and one to add and another to verify the addition [1]. Mark those steps in the last column. How someone working alone meets that wording is not settled in any FDA text found; the options (a trained second person, an automated weigh-and-verify system, or asking FDA in writing) are on quality control when you work alone, and bringing in help is on hiring and when you need separate quality control.
6. Batch production record
One for every batch. Answers 111.255 and 111.260, paragraph by paragraph [1].
| Header | Entry |
|---|
| Product; MMR number and version followed (111.255(c)) | |
| (a) Batch, lot or control number | |
| Date started | |
| (b) Equipment and processing lines used | |
| (c) Date and time of last maintenance, cleaning and sanitizing of each | |
| Balance check before use (reference weight, reading, pass or fail) | |
| (d) Component and your unique identifier | Supplier lot | (e) Weight or measure used | (j)(2) Weighed by | Weight verified by | Added by | Addition verified by |
|---|
| | | | | | |
| Time | Step from the MMR | (g) Actual monitoring result, or (h) test result | Initials |
|---|
| | | |
| Yield and packaging | Entry |
|---|
| Theoretical yield (from the MMR) | |
| (f) Actual yield; percentage of theoretical; within the MMR range? | |
| Packaging and closure lots used | |
| (k) Labels: issued = applied + damaged and destroyed + returned | ___ = ___ + ___ + ___ |
| Label version examined before use; matches MMR? | |
| Lot number and date applied | |
| Units bottled; units left over and their disposition | |
| Reserve samples taken (number, container) | |
| Quality control | Entry, signature, date |
|---|
| (i) Finished product specification results attached; met? | |
| (l)(1) Batch record reviewed, including monitoring and test results | |
| (l)(2) Reprocessing or repackaging approved or rejected | |
| (l)(3) Batch released or rejected for distribution | |
| (l)(4) Packaged and labeled product released or rejected | |
| (m) Material review and disposition, if any | |
| (n) Reprocessing, if any | |
7. In-process weight check sheet
One sheet per batch, kept with the batch record. Answers 111.75(b) (monitoring in-process points) and 111.260(g) and (h) (actual results) [1].
| Header | Entry |
|---|
| Product; batch number | |
| Target net fill per unit, mg | |
| Average empty shell weight, mg (20 shells) | |
| Scale ID; last check | |
| Your limits: average net fill within ___ percent of target; each unit within ___ | |
| Time | Plate or sample point | Units weighed | Average gross, mg | Lightest, mg | Heaviest, mg | Average net, mg | Net as percent of target | Within your limits? | Initials |
|---|
| | | | | | | | | |
For a 20-capsule sample, USP chapter 2091 (USP 38 edition, 2015) expects each capsule within 90 to 110 percent of the sample's average gross weight, with a net content test if any fall outside [5]. That test compares capsules with one another; your own limits compare them with your target, so the sheet carries both checks. The full procedure and why both are needed are on fill weight checks during a batch; tablet limits are on checking tablet quality.
8. Quality control review and release
One per batch, or as the quality control section of the batch record. Answers 111.113 (material review), 111.123(a)(8) and 111.127(h) (release), with 111.140(b)(2) for the signature [1].
| Check before release | Yes, no or n/a | Note |
|---|
| Batch made under the current approved MMR | | |
| Every component, package and label released from quarantine before use (111.120(e)) | | |
| Every weighing and addition verified and initialed | | |
| In-process specifications met | | |
| Actual yield within the MMR range | | |
| Label reconciliation adds up | | |
| Finished product specification results attached and met | | |
| Reserve samples collected and held (111.105(g)) | | |
| Material review (when a specification was not met, a deviation or unanticipated occurrence happened, or calibration may have failed) | Entry |
|---|
| What happened | |
| Investigation and findings | |
| Disposition decision (release, reprocess, reject) and reason | |
| Quality control signature and date | |
| Decision | Signature in the quality control role | Date |
|---|
| Batch released / rejected for distribution | | |
| Packaged and labeled lot released / rejected | | |
Equipment, samples and people
9. Equipment cleaning and calibration log
One log per piece of equipment, kept near it. Answers 111.35(b)(2) (use, maintenance, cleaning and sanitizing) and (b)(3) (each calibration) [1].
| Header | Entry |
|---|
| Equipment ID and description; location | |
| Cleaning procedure number | |
| Calibration frequency: before first use, then as specified in writing by the instrument's maker, or at a routine interval you set (111.27(b)) | |
| Date and time | Event (use, cleaning, sanitizing, maintenance, calibration) | Detail: procedure, reference used, reading, tolerance, pass or fail | Product or batch | Initials |
|---|
| | | | |
A failed calibration sends every batch weighed since the last good one to quality control for a material review (111.113) [1].
10. Reserve sample log
One line per lot distributed. Answers 111.83(b): identified by lot, in the container-closure system you sell, at least twice the quantity for all tests, held for the set period [1]. The retention period lives on records and reserve samples: 1 year past the shelf-life date if you use one, otherwise 2 years after distribution of the last batch.
| Product | Lot | Date packaged | Container-closure (same as sold?) | Units held | Units needed for one full set of tests (from template 2) | Storage location and conditions | Shelf-life date, if used | Date last unit shipped | Earliest discard date | Pulled for investigation: date, reason, units | Discarded: date, initials |
|---|
| | | | | | | | | | | |
11. Training record
Answers 111.14(b)(2): "Documentation of training, including the date of the training, the type of training, and the person(s) trained" [1]. Your own training counts, and so does naming who is responsible for quality control (111.12(b)) [1].
| Field | Entry |
|---|
| Person responsible for quality control operations (111.12(b)), named in writing | |
| Date | Person trained | Type of training | Trainer or source | Procedure or task | Evidence on file |
|---|
| | | | | |
After the sale
12. Complaint log, with adverse event record
One record per complaint. Part A answers 111.570(b)(2)(ii)(A) to (F) and the review steps in 111.560 [1]. Part B is filled in only when the complaint, or any other contact, describes an adverse event, and answers 21 U.S.C. 379aa-1 and FDA's guidance on it [3][4].
Part A: product complaint (21 CFR 111.560 and 111.570)
| Element | Entry |
|---|
| Complaint number | |
| (A) Name and description of the product | |
| (B) Batch, lot or control number, if available | |
| (C) Date received; complainant's name, address or phone, if available | |
| Channel (phone, email, marketplace message, review, in person) | |
| (D) Nature of the complaint, including how the product was used, if known | |
| Qualified person's review: could this be a failure to meet a specification or another Part 111 requirement? (111.560(a)(1)) Conclusion, name, date | |
| Decision to investigate or not, with reason; quality control approval, signature, date (111.560(b)) | |
| Batches and records reviewed: "all relevant batches and records" (111.560(c)) | |
| (F) Findings of the investigation and follow-up action | |
| Quality control approval of findings and follow-up, signature, date (111.560(b)) | |
| (E) Reply to the complainant, if any: date and content | |
| Linked records: return number, adverse event record, recall | |
| Closed: date, signature | |
Part B: adverse event record (21 U.S.C. 379aa-1)
| Element | Entry |
|---|
| Date and how the report was received (through the label contact or otherwise) | |
| Minimum data elements known? Identifiable patient / identifiable initial reporter / your firm's identity and contact / suspect dietary supplement / serious adverse event or fatal outcome [4] | ☐ ☐ ☐ ☐ ☐ |
| Attempts to obtain missing elements: dates and results | |
| Day 0: date all five were known | |
| Serious? Death, life-threatening experience, inpatient hospitalization, persistent or significant disability, birth defect, or medical or surgical intervention needed to prevent one of these [3] | Yes / No; reason |
| If serious: report due (15 business days after Day 0) [3] | |
| Submitted on MedWatch Form FDA 3500A: date, route (Safety Reporting Portal or mail), confirmation number [4][6] | |
| Copy of the label attached to the report [3] | ☐ |
| New medical information received within 1 year: date; follow-up report due 15 business days after receipt; date sent [3] | |
| Communications with the initial reporter and others: dates and summary [4] | |
| Keep until (6 years from the report, serious or not) [3] | |
Counting the business days, filing, and what belongs in the file are on serious adverse event reporting, which explains the 15-business-day and 6-year rules in full. If someone is in danger, call 911; for a possible poisoning, Poison Control is 1-800-222-1222.
13. Returned product log
One line per return. Answers subpart N: quarantine until quality control's material review (111.510), destruction unless the review decides otherwise (111.515), salvage and reprocessing only on quality control's decision (111.520, 111.525), investigation of other batches when implicated (111.530), and the records in 111.535(b) [1].
| Field | Entry |
|---|
| Return number; date received | |
| (b)(1) Written returns procedure followed: number and version | |
| Product; lot; quantity | |
| Customer reference; linked complaint number | |
| Reason given | |
| Quarantine location and label (111.510) | |
| (b)(2) Material review and disposition decision: destroy (the default), salvage, or reprocess; reason | |
| (b)(3) Results of any test or examination against product specifications | |
| (b)(4) If reprocessed: quality control's reevaluation and decision that it meets product specifications | |
| Other batches implicated? Investigation reference (111.530) | |
| Disposal: units, method, date, initials | |
| Quality control signature and date | |
14. Distribution record
One line per shipment. Answers 111.475(b)(2), "Records of product distribution," and supports 111.410(d), which requires that you can trace the packaged product's history "through distribution" by its lot number (111.415(f)) [1].
| Date shipped | Product and size | Lot | Quantity | Customer | Address or order ID | Channel | Initials |
|---|
| | | | | | | |
Run a traceability drill now and then: pick a lot and find every bottle in this record. How to do it is on holding and distributing product.
How long to keep them
Part 111 records are kept for 1 year past the shelf-life date if you use one, or 2 years after distribution of the last batch they relate to (111.605(a)), and must be available to FDA on request (111.610) [1]. Adverse event records have their own period of 6 years under 379aa-1 [3]; when one event sits in both files, keep it for the longer. The worked dates are on records and reserve samples.
Where to start filling them in
Specifications come first, because every other form refers to them. Start with templates 1 and 2 for your first product, and read writing specifications as you fill them in.