Which records do I need, and is there a template for each?

Updated

On this page9

If you manufacture, package, label or hold a dietary supplement, 21 CFR Part 111 expects written specifications, a master manufacturing record for each product, a batch record for every batch, and logs for equipment, reserve samples, training, distribution, complaints and returns, each signed or initialed when the work is done [1]. This page holds fourteen blank templates, one for each of those records, laid out as tables you can copy onto paper or into your own forms. Each one names the Part 111 section it answers and links to the page that explains the rule. The complaint template also carries the adverse event record that 21 U.S.C. 379aa-1 requires.

The fourteen records at a glance

#TemplatePart 111 sections it answers [1]Explained on
1Component specification111.70(b), 111.75(a)Writing specifications
2Finished product specification111.70(e), (g); 111.75(c)Writing specifications
3Supplier qualification record111.75(a)(2)(ii)(A) to (E)Qualifying a supplier
4Identity test record111.75(a)(1), 111.75(h)(1) and (h)(2)Identity testing for herbs
5Master manufacturing record (MMR)111.205, 111.210, 111.123(a)(1)The master manufacturing record
6Batch production record (BPR)111.255, 111.260The batch production record
7In-process weight check sheet111.75(b), 111.260(g), (h)Fill weight checks during a batch
8Quality control review and release111.113, 111.123(a)(8), 111.127(h), 111.140(b)(2)Quality control when you work alone
9Equipment cleaning and calibration log111.25, 111.27, 111.35(b)Cleaning and calibrating equipment
10Reserve sample log111.83(b), 111.465Records and reserve samples
11Training record111.12(b), 111.14(b)Training, hygiene and illness
12Complaint log, with adverse event record111.560, 111.570; 21 U.S.C. 379aa-1Handling product complaints and serious adverse event reporting
13Returned product log111.503 to 111.535Returned product
14Distribution record111.410(d), 111.415(f), 111.475(b)(2)Holding and distributing product

Each subpart also asks for written procedures, the "how we do it" documents behind these records; Part 111 at a glance lists them subpart by subpart. These templates are the "what we did" side.

How to set up the file

  • Number and version every form. A specification or master record carries a document number, a version and the date quality control approved it. Keep every superseded version, because batches made under it still point to it.
  • Write at the time. Part 111 asks for many entries to be documented "at the time of performance" (111.260(j) to (n), 111.570(b)(2)) [1]. Fill the form in as the step happens, in ink or in a system that records when each entry was made.
  • Sign in the role. Quality control entries need the date and the "Signature of the person performing the review, approval, or rejection" (111.140(b)(2)) [1]. If you are both maker and quality control, sign quality control entries as quality control, as a separate act; why that matters is on quality control when you work alone.
  • Paper or electronic. Records may be originals, true copies or electronic records, and "All electronic records must comply with part 11 of this chapter" (111.605(c)) [1]. A form filled in by hand and signed is an original.
  • Blanks are entries. Write "None" or "n/a" rather than leaving a line empty. FDA's warning letters have cited master records with required elements left out, as what FDA cites at small supplement makers shows.

Before production: specifications and suppliers

1. Component specification

One sheet per component: each dietary ingredient, the shell, each excipient. Answers 111.70(b) and 111.75(a) [1][2].

FieldEntry
Component name; specification number and version
Type: dietary ingredient, or other component
For a botanical: Latin binomial and plant part
Approved supplier(s)
Quality control approval: signature and date (111.105(a))
AttributeSpecification (limit)Method or examinationBasis or referenceChecked by your own test, or a qualified supplier's certificate?
IdentityDietary ingredient: your own test or examination, every lot (111.75(a)(1))
Purity
Strength
Composition
Lead
Arsenic
Cadmium
Mercury
Microbial limits
Moisture
Particle size
Allergen status and source
Storage conditions

A supplier's certificate can stand in for your test only for components that are not dietary ingredients, and for specifications other than a dietary ingredient's identity, after the supplier is qualified under template 3 [2].

2. Finished product specification

One sheet per product. Answers 111.70(e) for identity, purity, strength, composition and contaminant limits, and 111.70(g) for the packaged and labeled product [1].

FieldEntry
Product name; MMR number
Specification number and version; quality control approval, signature and date
Testing plan: every finished batch, or a sound statistical sampling plan (111.75(c))
AttributeSpecificationMethodUnits needed per test
Identity of each dietary ingredient
Strength: amount per serving of each declared ingredient
Composition
Contaminants: heavy metals
Contaminants: microbial
Appearance
Average net fill and spread
Disintegration, if adopted
Packaged and labeled: count, label version, lot number and date legible, seal intact
Units for one full set of testsTotal:
Reserve sample: at least twice the total (111.83(b)(4))Units:

3. Supplier qualification record

One record per supplier and material. Answers the five conditions in 111.75(a)(2)(ii) [2].

ConditionWhat to recordEntry
ScopeMaterial, and which specifications you will rely on the certificate for
(A) Confirm the supplier's resultsYour own or an independent lab's tests on supplier lots, compared side by side (table below)
(B) Certificate contentEach certificate shows the test method, the limits and the actual results; reject "conforms" with no numbers
(C) DocumentationWhere the qualification file is kept
(D) Periodic re-confirmationYour written interval and the reason for it
(E) Quality control approvalSignature and date
StatusQualified, suspended, re-qualified; dates and reasons
Supplier lotAttributeSupplier's resultYour resultLab and methodWithin your agreement criteria?

4. Identity test record

One record per lot of each dietary ingredient. Answers 111.75(a)(1); the method must be appropriate and scientifically valid (111.75(h)(1)) and of a kind listed in 111.75(h)(2) [1][2]. The fields follow identity testing for herbs.

FieldEntry
Component and specification number
Supplier, supplier lot, your receiving lot
Date received; date examined
Sample: containers sampled, amount
Method and procedure number
Reference used (voucher, authenticated reference material)
Observations, feature by feature against the specification
Result: pass, fail or inconclusive (inconclusive is not a pass)
Examined by; training record reference
Retained portion: where kept
Quality control review and disposition: released or rejected, signature, date

Making a batch

5. Master manufacturing record

One per formulation and batch size. Answers 111.205 and each paragraph of 111.210; quality control approves it and every change (111.123(a)(1)) [1].

FieldEntry
MMR number, version; quality control approval, signature and date
(a) Product name; strength of each dietary ingredient; batch size
(e) Intentional overage of any dietary ingredient, and why ("None" if none)
(f) Theoretical yield at each point; acceptable range that triggers an investigation, ___ to ___ percent
(g) Packaging description; representative label attached (version)
(h)(4) Special notations and precautions
(h)(5) Corrective action plan when a specification is not met
(b) ComponentSpecification number(c) Amount for this batch size(d) Declared amount per unit
Step(h)(3) Instruction(h)(1) Specification at this step(h)(2) Sampling and test procedureVerification by a second person?

For manual operations, 111.210(h)(3)(ii) calls for one person to weigh or measure and another to verify, and one to add and another to verify the addition [1]. Mark those steps in the last column. How someone working alone meets that wording is not settled in any FDA text found; the options (a trained second person, an automated weigh-and-verify system, or asking FDA in writing) are on quality control when you work alone, and bringing in help is on hiring and when you need separate quality control.

6. Batch production record

One for every batch. Answers 111.255 and 111.260, paragraph by paragraph [1].

HeaderEntry
Product; MMR number and version followed (111.255(c))
(a) Batch, lot or control number
Date started
(b) Equipment and processing lines used
(c) Date and time of last maintenance, cleaning and sanitizing of each
Balance check before use (reference weight, reading, pass or fail)
(d) Component and your unique identifierSupplier lot(e) Weight or measure used(j)(2) Weighed byWeight verified byAdded byAddition verified by
TimeStep from the MMR(g) Actual monitoring result, or (h) test resultInitials
Yield and packagingEntry
Theoretical yield (from the MMR)
(f) Actual yield; percentage of theoretical; within the MMR range?
Packaging and closure lots used
(k) Labels: issued = applied + damaged and destroyed + returned___ = ___ + ___ + ___
Label version examined before use; matches MMR?
Lot number and date applied
Units bottled; units left over and their disposition
Reserve samples taken (number, container)
Quality controlEntry, signature, date
(i) Finished product specification results attached; met?
(l)(1) Batch record reviewed, including monitoring and test results
(l)(2) Reprocessing or repackaging approved or rejected
(l)(3) Batch released or rejected for distribution
(l)(4) Packaged and labeled product released or rejected
(m) Material review and disposition, if any
(n) Reprocessing, if any

7. In-process weight check sheet

One sheet per batch, kept with the batch record. Answers 111.75(b) (monitoring in-process points) and 111.260(g) and (h) (actual results) [1].

HeaderEntry
Product; batch number
Target net fill per unit, mg
Average empty shell weight, mg (20 shells)
Scale ID; last check
Your limits: average net fill within ___ percent of target; each unit within ___
TimePlate or sample pointUnits weighedAverage gross, mgLightest, mgHeaviest, mgAverage net, mgNet as percent of targetWithin your limits?Initials

For a 20-capsule sample, USP chapter 2091 (USP 38 edition, 2015) expects each capsule within 90 to 110 percent of the sample's average gross weight, with a net content test if any fall outside [5]. That test compares capsules with one another; your own limits compare them with your target, so the sheet carries both checks. The full procedure and why both are needed are on fill weight checks during a batch; tablet limits are on checking tablet quality.

8. Quality control review and release

One per batch, or as the quality control section of the batch record. Answers 111.113 (material review), 111.123(a)(8) and 111.127(h) (release), with 111.140(b)(2) for the signature [1].

Check before releaseYes, no or n/aNote
Batch made under the current approved MMR
Every component, package and label released from quarantine before use (111.120(e))
Every weighing and addition verified and initialed
In-process specifications met
Actual yield within the MMR range
Label reconciliation adds up
Finished product specification results attached and met
Reserve samples collected and held (111.105(g))
Material review (when a specification was not met, a deviation or unanticipated occurrence happened, or calibration may have failed)Entry
What happened
Investigation and findings
Disposition decision (release, reprocess, reject) and reason
Quality control signature and date
DecisionSignature in the quality control roleDate
Batch released / rejected for distribution
Packaged and labeled lot released / rejected

Equipment, samples and people

9. Equipment cleaning and calibration log

One log per piece of equipment, kept near it. Answers 111.35(b)(2) (use, maintenance, cleaning and sanitizing) and (b)(3) (each calibration) [1].

HeaderEntry
Equipment ID and description; location
Cleaning procedure number
Calibration frequency: before first use, then as specified in writing by the instrument's maker, or at a routine interval you set (111.27(b))
Date and timeEvent (use, cleaning, sanitizing, maintenance, calibration)Detail: procedure, reference used, reading, tolerance, pass or failProduct or batchInitials

A failed calibration sends every batch weighed since the last good one to quality control for a material review (111.113) [1].

10. Reserve sample log

One line per lot distributed. Answers 111.83(b): identified by lot, in the container-closure system you sell, at least twice the quantity for all tests, held for the set period [1]. The retention period lives on records and reserve samples: 1 year past the shelf-life date if you use one, otherwise 2 years after distribution of the last batch.

ProductLotDate packagedContainer-closure (same as sold?)Units heldUnits needed for one full set of tests (from template 2)Storage location and conditionsShelf-life date, if usedDate last unit shippedEarliest discard datePulled for investigation: date, reason, unitsDiscarded: date, initials

11. Training record

Answers 111.14(b)(2): "Documentation of training, including the date of the training, the type of training, and the person(s) trained" [1]. Your own training counts, and so does naming who is responsible for quality control (111.12(b)) [1].

FieldEntry
Person responsible for quality control operations (111.12(b)), named in writing
DatePerson trainedType of trainingTrainer or sourceProcedure or taskEvidence on file

After the sale

12. Complaint log, with adverse event record

One record per complaint. Part A answers 111.570(b)(2)(ii)(A) to (F) and the review steps in 111.560 [1]. Part B is filled in only when the complaint, or any other contact, describes an adverse event, and answers 21 U.S.C. 379aa-1 and FDA's guidance on it [3][4].

Part A: product complaint (21 CFR 111.560 and 111.570)

ElementEntry
Complaint number
(A) Name and description of the product
(B) Batch, lot or control number, if available
(C) Date received; complainant's name, address or phone, if available
Channel (phone, email, marketplace message, review, in person)
(D) Nature of the complaint, including how the product was used, if known
Qualified person's review: could this be a failure to meet a specification or another Part 111 requirement? (111.560(a)(1)) Conclusion, name, date
Decision to investigate or not, with reason; quality control approval, signature, date (111.560(b))
Batches and records reviewed: "all relevant batches and records" (111.560(c))
(F) Findings of the investigation and follow-up action
Quality control approval of findings and follow-up, signature, date (111.560(b))
(E) Reply to the complainant, if any: date and content
Linked records: return number, adverse event record, recall
Closed: date, signature

Part B: adverse event record (21 U.S.C. 379aa-1)

ElementEntry
Date and how the report was received (through the label contact or otherwise)
Minimum data elements known? Identifiable patient / identifiable initial reporter / your firm's identity and contact / suspect dietary supplement / serious adverse event or fatal outcome [4]☐ ☐ ☐ ☐ ☐
Attempts to obtain missing elements: dates and results
Day 0: date all five were known
Serious? Death, life-threatening experience, inpatient hospitalization, persistent or significant disability, birth defect, or medical or surgical intervention needed to prevent one of these [3]Yes / No; reason
If serious: report due (15 business days after Day 0) [3]
Submitted on MedWatch Form FDA 3500A: date, route (Safety Reporting Portal or mail), confirmation number [4][6]
Copy of the label attached to the report [3]☐
New medical information received within 1 year: date; follow-up report due 15 business days after receipt; date sent [3]
Communications with the initial reporter and others: dates and summary [4]
Keep until (6 years from the report, serious or not) [3]

Counting the business days, filing, and what belongs in the file are on serious adverse event reporting, which explains the 15-business-day and 6-year rules in full. If someone is in danger, call 911; for a possible poisoning, Poison Control is 1-800-222-1222.

13. Returned product log

One line per return. Answers subpart N: quarantine until quality control's material review (111.510), destruction unless the review decides otherwise (111.515), salvage and reprocessing only on quality control's decision (111.520, 111.525), investigation of other batches when implicated (111.530), and the records in 111.535(b) [1].

FieldEntry
Return number; date received
(b)(1) Written returns procedure followed: number and version
Product; lot; quantity
Customer reference; linked complaint number
Reason given
Quarantine location and label (111.510)
(b)(2) Material review and disposition decision: destroy (the default), salvage, or reprocess; reason
(b)(3) Results of any test or examination against product specifications
(b)(4) If reprocessed: quality control's reevaluation and decision that it meets product specifications
Other batches implicated? Investigation reference (111.530)
Disposal: units, method, date, initials
Quality control signature and date

14. Distribution record

One line per shipment. Answers 111.475(b)(2), "Records of product distribution," and supports 111.410(d), which requires that you can trace the packaged product's history "through distribution" by its lot number (111.415(f)) [1].

Date shippedProduct and sizeLotQuantityCustomerAddress or order IDChannelInitials

Run a traceability drill now and then: pick a lot and find every bottle in this record. How to do it is on holding and distributing product.

How long to keep them

Part 111 records are kept for 1 year past the shelf-life date if you use one, or 2 years after distribution of the last batch they relate to (111.605(a)), and must be available to FDA on request (111.610) [1]. Adverse event records have their own period of 6 years under 379aa-1 [3]; when one event sits in both files, keep it for the longer. The worked dates are on records and reserve samples.

Where to start filling them in

Specifications come first, because every other form refers to them. Start with templates 1 and 2 for your first product, and read writing specifications as you fill them in.

References

  1. Electronic Code of Federal Regulations, 21 CFR Part 111 (sections 111.12, 111.14, 111.25, 111.27, 111.35, 111.70, 111.75, 111.83, 111.105, 111.113, 111.120, 111.123, 111.127, 111.140, 111.205, 111.210, 111.255, 111.260, 111.410, 111.415, 111.465, 111.475, subparts N and O, 111.605, 111.610), up to date as of August 13, 2026, read November 19, 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-B/part-111
  2. Legal Information Institute, Cornell Law School, 21 CFR 111.75, What must you do to determine whether specifications are met?, paragraphs (a)(1), (a)(2)(ii)(A) to (E) and (h), read November 19, 2026. https://www.law.cornell.edu/cfr/text/21/111.75
  3. Legal Information Institute, 21 U.S.C. 379aa-1, Serious adverse event reporting for dietary supplements (subsections (a) to (h)), read November 19, 2026. https://www.law.cornell.edu/uscode/text/21/379aa-1
  4. U.S. Food and Drug Administration, Guidance for Industry: Questions and Answers Regarding Adverse Event Reporting and Recordkeeping for Dietary Supplements (revised September 2013; page content current as of September 20, 2018), read November 19, 2026. https://www.fda.gov/food/guidance-documents-regulatory-information-topic/guidance-industry-questions-and-answers-regarding-adverse-event-reporting-and-recordkeeping-dietary
  5. United States Pharmacopeia, General Chapter 2091, Weight Variation of Dietary Supplements, USP 38 to NF 33 (2015), as reproduced by DrugFuture, read November 19, 2026. https://www.drugfuture.com/Pharmacopoeia/usp38/data/v38332/usp38nf33s2_c2091.html
  6. U.S. Food and Drug Administration, MedWatch: FDA Safety Information and Adverse Event Reporting Program, mandatory reporting instructions for Form FDA 3500A (edition 09/2025), read November 19, 2026. https://www.fda.gov/about-fda/forms/medwatch-fda-safety-information-and-adverse-event-reporting-program-mandatory-instructions