What checks does each tablet batch need?

Updated

On this page9

Every tablet batch needs four physical checks: weight variation, hardness, friability (how much the tablets chip and dust when tumbled) and disintegration. You set the limits for each in your own written specification, as federal law requires, and you can borrow the methods from USP and from pharmacy teaching labs. In the 2015 edition of USP, the weight limits for tablet supplements depend on tablet weight: 10 percent for tablets of 130 mg or less, 7.5 percent up to 324 mg and 5 percent above that. UNC's pharmacy lab gives about 4 to 8 or 10 kg as a hardness range for oral tablets. This page sets out each check, its reference figure and how to record it.

The four checks at a glance

CheckWhat it tells youReference method and figureEquipment
Weight variationWhether each tablet holds about the same amountUSP 2091 (USP 38): 20 tablets; limits by average weight, below [1]Scale reading to 1 mg
Hardness (breaking force)Whether tablets are strong enough to survive bottling and handlingUNC pharmlabs: about 4 to 8 or 10 kg for oral tablets [2]Hardness tester
FriabilityWhether tablets chip, cap or dust in the bottleUSP 1216 (USP 38): mean weight loss of not more than 1.0 percent is acceptable for most products [3]Friability drum, or a contract lab
DisintegrationWhether tablets break apart in liquid in timeUSP 2040; times and method on disintegration and USP standardsDisintegration apparatus, or a contract lab

The USP chapters are reference methods. Under 21 CFR Part 111 you must "establish in-process specifications for any point, step, or stage" in the master manufacturing record "where control is necessary," and finished batch specifications for identity, purity, strength and composition [4]. The figures here help you set those limits; your written specification is what binds you. Current USP text sits behind USP's subscription. The USP figures on this page are from USP 38 to NF 33 (2015), the edition read, and current text may differ.

Weight variation

USP chapter 2091, Weight Variation of Dietary Supplements, as published in USP 38 [1]:

  1. Weigh 20 whole tablets one at a time and calculate the average.
  2. No more than 2 tablets may differ from the average by more than the percentage in the table, and none may differ by more than double that percentage.
Average tablet weightPercentage difference allowedDouble, which no tablet may exceed
130 mg or less10 percent20 percent
More than 130 mg through 324 mg7.5 percent15 percent
More than 324 mg5 percent10 percent

The same limits apply to uncoated and film coated tablets. Other coated tablets (sugar coated, for example) are weighed whole, and if they fail, their cores are weighed after the coating is washed off [1].

Like the capsule test, this compares tablets with their own average. A batch that is uniformly light can pass. Your specification should also set a limit for the average against your target weight, which is how you know the label amount is in each tablet. UNC's compounding lab applies a different check, which it attributes to guidelines in USP 24/NF 19 Supplement 1: each tablet "not less than 90% and not more than 110% of the theoretically calculated weight" [2]. Setting the target is on setting tablet weight and die fill.

Hardness

Hardness is the force needed to break a tablet across its diameter. UNC's compounding lab measures it by applying a load across the tablet until it breaks, and gives these approximate ranges [2]:

Tablet typeApproximate hardness (UNC pharmlabs)
Oral tablets4 to 8 or 10 kg
Chewable tablets3 kg ("much softer")
Some sustained release tablets10 to 20 kg

Testers report in different units. FDA's 2018 guidance on chewable tablets gives the conversions: "1 kp = 1 kgf = 9.8 N = 1.4 scu" (kilopond, kilogram force, newton and Strong-Cobb unit) [5]. Pick one unit, use it in your specification and records, and do not mix them.

Hardness interacts with everything else. Too soft and tablets chip and fail friability; too hard and they may not disintegrate in time. Set your range from trials that check both.

Friability

Friability is weight lost when tablets tumble against each other, which predicts chipping and dusting in the bottle. USP chapter 1216, as published in USP 38 [3]:

  1. Dedust the tablets.
  2. For tablets of 650 mg or less, take whole tablets weighing as near as possible to 6.5 g; for tablets over 650 mg, take 10 whole tablets.
  3. Weigh accurately and place in a drum rotating at 25 revolutions per minute, with a curved projection inside that drops the tablets at each turn.
  4. Rotate 100 times, remove, dedust and reweigh.
  5. A mean weight loss of not more than 1.0 percent is acceptable for most products. Any obviously cracked, cleaved or broken tablet fails the sample. If the result is hard to interpret or exceeds the target, run the test twice more and use the mean of three.

Chapter 1216 is a general information chapter, and it notes that chewable and effervescent tablets may have different friability specifications [3]. The chapter fixes the drum's dimensions (an internal diameter of 283 to 291 mm, for example) [3], so a homemade tumbler does not give comparable results. If you do not own a drum, a contract lab can run the test on samples from each batch.

Disintegration

Disintegration is the test that tells you whether the tablet comes apart in liquid within a set time. USP 2040 sets the method and times, which are set out on disintegration and USP standards. UNC's pharmacy lab describes a simple homemade check, a 10 mesh screen held about 2 inches above the bottom of a beaker of stirred water, with 15 to 30 minutes as a reasonable time [2]. That check is useful during development; for a specification, use a method you can justify and repeat.

Sampling across a run

One sample at the end of a run can miss a drift in the middle. A workable pattern for a small press, which you write into your master manufacturing record:

WhenWhat
Start of run, after setupWeight and hardness of a sample, size set in your master manufacturing record; adjust before continuing
At set intervals during the runWeight and hardness of a few tablets each time; interval set by you
Whenever you refill the hopper with a new container of blend, or after any stopWeight and hardness
End of runFull weight variation (20 tablets), hardness set, friability and disintegration samples

Keep tablets from each interval separate until that interval's check is recorded, so a failure affects only tablets you can identify.

The record for each check

Part 111 requires the batch production record to hold "[t]he actual results obtained during any monitoring operation" and the results of any testing or examination performed during the batch [6]. For each check, write the date and time, the sample point, the instrument and its calibration status, the individual results or the average and range, the result against your specification, and your initials. A blank layout is on Part 111 record templates.

When a check fails

A failed hardness or friability result, or tablets that split in the drum, usually points to compression force, trapped air, tooling or the blend's flow. The causes and fixes are on tablets that cap, laminate or crumble. Physical checks say nothing about identity or strength; those are laboratory tests on finished product, set out on testing finished product.

References

  1. United States Pharmacopeia, General Chapter 2091, Weight Variation of Dietary Supplements, USP 38 to NF 33 (2015), as reproduced by DrugFuture, read November 19, 2026. https://www.drugfuture.com/Pharmacopoeia/usp38/data/v38332/usp38nf33s2_c2091.html
  2. UNC Eshelman School of Pharmacy, Pharmlabs, Tablets, copyright 1996 to 2026, read November 19, 2026. https://pharmlabs.unc.edu/labexercises/compounding/tablets
  3. United States Pharmacopeia, General Chapter 1216, Tablet Friability, USP 38 to NF 33 (2015), as reproduced by DrugFuture, read November 19, 2026. https://www.drugfuture.com/Pharmacopoeia/usp38/data/v38332/usp38nf33s2_c1216.html
  4. Legal Information Institute, Cornell Law School, 21 CFR 111.70, What specifications must you establish?, read November 19, 2026. https://www.law.cornell.edu/cfr/text/21/111.70
  5. U.S. Food and Drug Administration, Center for Drug Evaluation and Research, Quality Attribute Considerations for Chewable Tablets, Guidance for Industry, August 2018, read November 19, 2026. https://www.fda.gov/media/98598/download
  6. Legal Information Institute, Cornell Law School, 21 CFR 111.260, What must the batch record include?, paragraphs (g) and (h), read November 19, 2026. https://www.law.cornell.edu/cfr/text/21/111.260