How much of my powder will each capsule hold?
Updated
On this page7
Enter your powder's bulk density, or the weight of a measured volume of it, and the calculator multiplies each capsule size's volume by that density to give the most powder, in milligrams, that one capsule of each size can hold at that density. It also gives capsules per 100 g of powder. Run it backward with the amount of powder you want per serving and it finds the smallest size that holds it in a set number of capsules. The capsule volumes are the published figures from the shell maker and a pharmacy school. Every result is a theoretical maximum: the weight on your label comes from weighing filled capsules.
What you need before you start
Your powder's bulk density, measured by you. The calculator has no density built in and will not suggest one. No published table of bulk densities for common herb powders could be found, and density changes with the grind, the plant part, moisture and how the powder has settled, so one lot's figure does not carry over to the next. Measure each lot. The method, from United States Pharmacopeia general chapter <616> [3] and as a home version with a 100 mL graduated cylinder, is on measuring bulk density.
You can enter density in either of two ways:
| Input | What you type | What the calculator does |
|---|---|---|
| Bulk density | The figure you measured, in g/mL | Uses it as entered |
| A weighed volume | Grams of powder and the milliliters it filled when poured, without tapping | Divides grams by milliliters: for example, 52.4 g in 87 mL gives 0.6023 g/mL |
| Tapped volume (optional) | The volume after tapping until it stops settling | Adds a second column at tapped density, plus the compressibility index and Hausner ratio |
Your shell size, or your shell maker's sheet. The calculator lists the sizes whose volumes a shell maker or a pharmacy school publishes. If your capsules come from another maker, enter the volume from that maker's size sheet in the custom row, because dimensions can differ slightly between makers and between materials [1].
The volumes it uses
These are the figures, and the sources, used on capsule sizes and volumes, which explains the sizes in full; when that page changes, the calculator changes with it.
| Size | Volume used, mL | Source |
|---|---|---|
| 000 | 1.37 | UNC Eshelman School of Pharmacy [2] |
| 00 | 0.95 | Capsugel (Lonza) size sheet, April 2013 [1] |
| 0EL | 0.78 | Capsugel [1] |
| 0 | 0.68 | Capsugel [1] |
| 1 | 0.50 | Capsugel [1] |
| 2 | 0.37 | Capsugel [1] |
| 3 | 0.30 | Capsugel [1] |
| 4 | 0.21 | Capsugel [1]; UNC gives 0.20 [2] |
| 5 | 0.13 | UNC [2] |
The two sources agree on sizes 00, 0, 1, 2 and 3 and differ only on size 4, so the calculator shows UNC's 0.20 mL as a note beside size 4. Sizes 00EL, 1EL and 2EL are made, but no published volume for them could be found, so they are not offered; use the custom row with your maker's figure.
The arithmetic
Fill weight (mg) = capsule volume (mL) × bulk density (g/mL) × 1,000
Capsules per 100 g = 100,000 mg ÷ fill weight per capsule, rounded down
Capsugel presents capacity the same way, as volume times density at a range of densities [1]. At a density of 0.6 g/mL, for example, a size 00 holds 0.95 × 0.6 × 1,000 = 570 mg, and 100 g of that powder fills 175 capsules. Read across and the reason for measuring is plain: at 1.0 g/mL the same size 00 holds 950 mg. The worked tables at 0.6, 0.8 and 1.0 g/mL are on how much powder fits in a capsule; the calculator reproduces them exactly.
If you also entered a tapped volume
A capsule filled on a manual machine sits somewhere between poured and tapped density: spreading powder over the plate is close to pouring, and each tamp pushes it toward the tapped figure, as measuring bulk density explains. So the calculator gives two columns, poured and tapped, and your weighed fill should fall between them. It also reports the two ratios USP gives from the same readings, which USP describes as measures of how readily a powder compresses and uses, with the two densities, to evaluate powder flow [3]:
- Compressibility index = 100 × (poured volume minus tapped volume) ÷ poured volume
- Hausner ratio = poured volume ÷ tapped volume
With example readings of 52.4 g at 87 mL poured and 70 mL tapped, the index is 19.5 and the ratio 1.24. A powder that settles a lot usually flows poorly and fills unevenly; flow agents and fillers covers the options.
Running it backward: from an amount to a size
Enter the amount of powder you want in one serving and your measured density. The amount is your decision, made with your health professional or from your own formula; the calculator recommends none. It returns, for every size:
| Column | Arithmetic |
|---|---|
| Fill per capsule | volume × density × 1,000 |
| Capsules needed | amount ÷ fill per capsule, rounded up |
| What each capsule must hold | amount ÷ capsules needed |
| Share of a full capsule | what each must hold ÷ fill per capsule |
Then it names two sizes: the smallest that holds the whole amount in one capsule, if any does, and the smallest that holds it within the most capsules per serving you are willing to take. "Smallest" means smallest volume, so size 0 (0.68 mL) counts as smaller than 0EL (0.78 mL).
With the example inputs from how much powder fits, 1,000 mg of powder at 0.6 g/mL (example inputs, not a recommended amount), no size holds it in one capsule; a size 000 holds 822 mg. Within two capsules the smallest size is 00, at 500 mg each, 87.7 percent of a full capsule. Within three it is size 0, at 333.3 mg each.
The last column matters on a manual machine, because capsules come off the plate full. If each capsule must hold less than a full fill, you can change size, change the number of capsules per serving, or add a filler to take up the space. A filler changes your label and your Part 111 records; how much powder fits sets out the three choices.
Why the scale has the last word
Tamping packs more powder in than the poured density predicts. Air pockets leave less. The cap's overlap may hold a little powder or none. A new lot may settle differently. For those reasons the figures here are for choosing a size and estimating how much powder to buy, and the amount you declare comes from weighing filled capsules: net fill is the gross weight of filled capsules minus the average weight of empty shells, as shown on checking your first batch. If you sell what you make, Part 111 requires fill weight to be checked against your own written specification during each batch, set out on fill weight checks during a batch.
From fill weight to a serving
Once you have weighed your filled capsules, take the real net fill per capsule to the servings and dosing calculator, which works out capsules per serving, servings per bottle and the amount of each ingredient for your Supplement Facts panel.
Top picks
Top containers for capsules and tablets
300 cc · 45-400 · PET · Amber
500 cc · 53-400 · PET
200 cc · 38-400 · PET
120 cc · 38-400 · PET · Clear
120 cc · 38-400 · PET · Amber
300 cc · 45-400 · PET · Clear
120 cc · 38-400 · PET · Amber
175 cc · 38-400 · PET
References
- Capsugel (Lonza), Vcaps Capsule Size Information, last updated April 2013, read November 19, 2026. https://www.capsugel.com/cpsl-web/kc/library/Capsugel_Vcaps_Sizing_Information_1.pdf
- UNC Eshelman School of Pharmacy, Pharmlabs, Capsules, copyright 1996 to 2026, read November 19, 2026. https://pharmlabs.unc.edu/labexercises/compounding/capsules/
- United States Pharmacopeia, General Chapter 616, Bulk Density of Powders, Stage 4 harmonization text, official August 1, 2025, read November 19, 2026. https://usp.org/sites/default/files/usp/document/our-work/reference-standards/20240927HSm99375.pdf