How do I qualify a supplier so I can rely on its certificate of analysis?
Updated
On this page8
You qualify a supplier by proving, with your own testing, that its certificates of analysis can be trusted, then writing that proof down and checking it again at intervals you set. Part 111 lists five conditions in 111.75(a)(2)(ii): confirm the supplier's results, make sure each certificate shows methods, limits and actual results, keep documentation of how you qualified the supplier, periodically re-confirm, and have quality control approve the documentation. Once qualified, the certificate can stand in for your own tests of other components and of specifications other than a dietary ingredient's identity. This page turns those conditions into a written procedure and sets out when a supplier loses its status.
What qualification lets you do, and what it does not
A qualified supplier's certificate of analysis (CoA, the supplier's report of test results for one lot) can replace your own testing for:
- the identity of components that are not dietary ingredients, such as fillers, flow agents and capsule shells;
- the other specifications of any component, including a dietary ingredient's purity, strength, composition and contaminant limits [1].
It cannot replace your identity test or examination of a dietary ingredient. FDA said so in the 2007 final rule: firms "may not rely upon a certificate of analysis provided by suppliers to determine the identity" of a dietary ingredient [2]. That rule and its exemption petition are on what Part 111 requires you to test.
The five conditions in 111.75(a)(2)(ii)
| Condition | What the rule asks | What it looks like in practice |
|---|---|---|
| (A) Qualify the supplier | "You first qualify the supplier by establishing the reliability of the supplier's certificate of analysis through confirmation of the results of the supplier's tests or examinations" [1] | You test lots yourself, or through an independent lab, and compare your results with the supplier's |
| (B) Certificate content | "The certificate of analysis includes a description of the test or examination method(s) used, limits of the test or examinations, and actual results of the tests or examinations" [1] | Reject a certificate that says only "conforms" or "pass" with no numbers or method |
| (C) Documentation | "You maintain documentation of how you qualified the supplier" [1] | A qualification file per supplier and material |
| (D) Periodic re-confirmation | "You periodically re-confirm the supplier's certificate of analysis" [1] | A schedule you wrote and follow, with results filed |
| (E) Quality control approval | "Your quality control personnel review and approve the documentation setting forth the basis for qualification" (and re-qualification) of any supplier [1] | A signed and dated approval in the file |
A qualification procedure you can write down
Part 111 does not prescribe how many lots to test or how close your results must be. Those are your decisions, and the procedure is where you make them and justify them. One workable outline:
- Name the scope. One supplier, one material, the specifications you intend to rely on the CoA for (for example, lead, arsenic, cadmium, mercury, total aerobic count, yeast and mold). Qualification is for that scope; a second material from the same supplier is a separate decision.
- Collect the supplier's documents. Specification sheet, a sample certificate, the methods it uses, the lab that runs them and that lab's accreditation, and the supplier's answers to your questionnaire (origin, processing, how it controls contamination). Buying ingredients lists what to request with each lot.
- Decide how many lots you will confirm and how. Write the number and the reason. More lots give more confidence; a material with known contamination risk deserves more. Send the samples to an independent lab using methods suited to the material (choosing a lab).
- Set your agreement criteria before you see results. For example, both results within your specification, and your result and the supplier's within a tolerance you justify from the method's precision. Deciding afterward invites you to accept whatever came back.
- Compare and record. Line up each lot's supplier result beside yours, by test.
- Quality control approves or rejects the qualification, with a signature and date, and the approved scope written out.
- Set the re-confirmation schedule (next section) and put the first date on your calendar.
Until a supplier is qualified, test each lot yourself against every specification you need.
How often to re-confirm
The rule says "periodically" and sets no interval [1]. FDA's 2007 preamble does not set one either [2]. Choose one, write it down, and give a reason. Factors that justify more frequent re-confirmation:
- the material has a known contamination risk, or the specification is close to its limit in past results;
- the supplier changed its source, site, process or lab;
- you have had any discrepancy with this supplier before;
- the material is a large share of the finished product, so an error in it moves the finished result most.
One structure you could write is a confirmatory test on a set fraction of incoming lots, or on the first lot after a set time has passed, whichever comes first. Whatever you choose, the file should show it was followed.
When a supplier loses its status
Write these triggers into the procedure so the decision is not made in the moment:
| Event | What to do |
|---|---|
| Your confirmatory result disagrees with the certificate beyond your criterion | Suspend reliance; test incoming lots yourself; investigate with the supplier; quality control decides whether to re-qualify |
| A certificate arrives without method, limits or actual results | Do not accept it as a basis for release; ask for a complete one or test the lot |
| A certificate looks generic or recycled (same numbers lot after lot, mismatched lot numbers or dates) | Treat as a discrepancy; see reading a certificate of analysis |
| The supplier changes source, manufacturing site, process or testing lab | Re-qualify for the affected scope |
| A re-confirmation is missed | Reliance lapses until it is done; test lots in the meantime |
| A complaint or adverse event traces to the material | Suspend and investigate |
Reinstating a supplier means repeating the qualification steps for the affected scope, with a fresh quality control approval.
The qualification file
One folder per supplier and material, holding:
- the scope (material, specifications relied on);
- the supplier's specification sheet, sample certificate and questionnaire;
- your confirmatory test reports, with the lab's name and methods;
- the side-by-side comparison and your agreement criteria;
- quality control's approval, signed and dated;
- the re-confirmation schedule and each re-confirmation result;
- any suspension, investigation and re-qualification.
Section 111.95(b)(2) lists "Documentation of your qualification of a supplier for the purpose of relying on the supplier's certificate of analysis" among the subpart E records [4], and FDA's compliance guide repeats it [3]. Retention is set by 111.605 and explained on records and reserve samples. A blank qualification form is on record templates.
Then read each certificate as it arrives
Qualification tells you a supplier's certificates can be trusted in general. You still read each one, lot by lot, against your specification. Reading a certificate of analysis shows what each line should say.
Top picks
Top containers for capsules and tablets
300 cc · 45-400 · PET · Amber
500 cc · 53-400 · PET
200 cc · 38-400 · PET
120 cc · 38-400 · PET · Clear
120 cc · 38-400 · PET · Amber
300 cc · 45-400 · PET · Clear
120 cc · 38-400 · PET · Amber
175 cc · 38-400 · PET
References
- Legal Information Institute, Cornell Law School, 21 CFR 111.75, What must you do to determine whether specifications are met?, paragraph (a)(2)(ii)(A) to (E), checked word for word against current text November 19, 2026. https://www.law.cornell.edu/cfr/text/21/111.75
- U.S. Food and Drug Administration, Current Good Manufacturing Practice in Manufacturing, Packaging, Labeling, or Holding Operations for Dietary Supplements, final rule, 72 FR 34752, June 25, 2007, preamble at 34836 and Comment 174 at 34846 to 34848, read November 19, 2026. https://www.govinfo.gov/content/pkg/FR-2007-06-25/html/07-3039.htm
- U.S. Food and Drug Administration, Small Entity Compliance Guide: Current Good Manufacturing Practice in Manufacturing, Packaging, Labeling, or Holding Operations for Dietary Supplements, December 2010, read November 19, 2026. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/small-entity-compliance-guide-current-good-manufacturing-practice-manufacturing-packaging-labeling
- Electronic Code of Federal Regulations, 21 CFR Part 111, section 111.95, up to date as of August 13, 2026, read November 19, 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-B/part-111