Which tests does Part 111 require, and which can rest on a supplier's certificate?

Updated

On this page8

Part 111, FDA's manufacturing rule for dietary supplements, requires you to run at least one appropriate test or examination to confirm the identity of every dietary ingredient before you use it, unless FDA grants you an exemption by petition. A supplier's certificate of analysis (CoA) can stand in for your own testing only for other components and other specifications, and only after you have qualified that supplier. Finished batches are checked against your finished product specifications, either every batch or a subset chosen by a sound statistical sampling plan. This page sets out each requirement, the section behind it, and the records that prove you met it.

The rule in four parts

All of these requirements sit in subpart E of 21 CFR Part 111 [1]. They apply to every supplement form, whether capsule, tablet, gummy, powder or liquid.

1. Identity of each dietary ingredient, by you. Before you use any dietary ingredient, 111.75(a)(1)(i) says you must "Conduct at least one appropriate test or examination to verify the identity of any component that is a dietary ingredient" [2]. A dietary ingredient is the herb, vitamin, mineral, amino acid or other substance the product is sold for, as opposed to fillers, flow agents and the capsule shell. FDA said in the 2007 final rule that firms "may not rely upon a certificate of analysis provided by suppliers to determine the identity" of a dietary ingredient before use [4].

2. Everything else about components, by you or by a qualified supplier's certificate. For components that are not dietary ingredients, and for the other specifications of every component (purity, strength, composition, contamination limits), you must confirm identity and determine whether specifications are met, either by your own tests or by relying on a supplier's certificate of analysis under the conditions in 111.75(a)(2)(ii) [2].

3. In-process checks. You must monitor the in-process control points, steps or stages your master manufacturing record names, to see whether in-process specifications are met (111.75(b)) [2]. For a capsule or tablet maker, fill weight and tablet weight checks are the usual examples.

4. Finished batches. For a subset of finished batches identified through a sound statistical sampling plan, or for every finished batch, you must verify that the finished product meets its specifications for identity, purity, strength, composition and contamination limits (111.75(c)) [2]. Representative samples of finished batches are collected under the same choice: "a sound statistical sampling plan (or otherwise every finished batch)" (111.80(c)) [1].

The tests and examinations you use must be "appropriate, scientifically valid methods" (111.75(h)(1)), and under 111.75(h)(2) they "must include at least one of the following": gross organoleptic analysis, macroscopic analysis, microscopic analysis, chemical analysis, or other scientifically valid methods [2].

What to test, when, and the section behind it

WhatWhenWhat the rule requiresCan a supplier CoA stand in?Section
Identity of each dietary ingredientEach lot, before useAt least one appropriate test or examinationNo, unless FDA grants a petition111.75(a)(1)
Identity of other components (fillers, flow agents, shells)Each lot, before useConfirm identityYes, after the supplier is qualified111.75(a)(2)
Other component specifications (purity, strength, composition, contaminants)Each lot, before useDetermine whether specifications are metYes, after the supplier is qualified111.75(a)(2)
In-process specificationsDuring each batch, at the points in your MMRMonitor to detect deviationsNo111.75(b)
Finished batch specificationsEvery batch, or batches chosen by a sound statistical sampling planVerify identity, purity, strength, composition, contaminant limitsNo111.75(c), 111.80(c)
Finished specifications you cannot test at the endWhen documentedShow how other testing or monitoring assures themNot applicable111.75(d)
Product received for packaging or labeling onlyEach shipmentVisual examination and documentation that 111.70(f) specifications are metDocumentation required111.75(e)
Containers, closures and labelsBefore useVisual identification and review of the supplier's invoice, guarantee or certificationYes, by review111.75(f)
Packaged and labeled productEach batchVisual check that the right packaging and label were usedNo111.75(g)

Sources: 21 CFR 111.75 [2]; 111.80 [1].

The specifications themselves are your choice. Part 111 tells you what categories they must cover and requires you to meet them; it does not hand you numbers. How to write them is on writing specifications.

"My supplier's CoA is enough"

Small makers often believe a supplier's certificate settles everything. For dietary ingredients the rule says otherwise. A certificate of analysis is the supplier's own statement of its test results for a lot. Part 111 lets you rely on one only for components that are not dietary ingredients and for specifications other than the identity of a dietary ingredient, and then only when all five conditions in 111.75(a)(2)(ii) are met [2]:

  • (A) you first qualify the supplier by "establishing the reliability of the supplier's certificate of analysis through confirmation of the results of the supplier's tests or examinations";
  • (B) "The certificate of analysis includes a description of the test or examination method(s) used, limits of the test or examinations, and actual results of the tests or examinations";
  • (C) "You maintain documentation of how you qualified the supplier";
  • (D) "You periodically re-confirm the supplier's certificate of analysis"; and
  • (E) your quality control personnel review and approve the documentation setting out the basis for qualifying (and re-qualifying) the supplier.

FDA's compliance guide for small businesses repeats the identity duty in plain terms: you must "conduct at least one appropriate test or examination to verify the identity of any dietary ingredient" [3]. The guide is FDA's plain-language explanation of the rule, dated December 2010; the rule itself is what binds you.

So for an herb capsule, the herb lot needs your identity test or examination. The rice flour and the capsule shells can rest on a qualified supplier's paperwork. The herb lot's heavy metals and microbial results can also rest on that supplier's CoA, once you have qualified it for those tests. The procedure is on qualifying a supplier.

The petition route

111.75(a)(1)(ii) lets you ask FDA to exempt you from testing every lot of a dietary ingredient. "You may submit a petition, under 21 CFR 10.30, to request an exemption" [2]. The petition must show, with scientific rationale and supporting data, that "there is no material diminution of assurance, compared to the assurance provided by 100 percent identity testing" [2]. In practice, this means a statistical or historical case that a reduced testing plan for that ingredient from that supplier is as reliable as testing every lot. FDA reviews the petition, and until it grants one you test every lot. No published list of granted petitions was found for this page; if you are considering one, ask FDA first and expect to need a body of your own test data.

The petition is a route for an established firm with records. A new maker has no history to show, so it does not apply at the start.

What this means if you work alone

The same person can run tests and make decisions, but the rule assigns approvals to quality control: quality control personnel approve the supplier qualification documentation (111.75(a)(2)(ii)(E)), approve the basis for finished batch testing (111.75(c)(4)) and approve any 111.75(d) exemption [2]. FDA's compliance guide says quality control personnel "conduct all required material reviews and make all required disposition decisions" [3]. How one person keeps those roles distinct is on quality control when you work alone.

A realistic first-year testing pattern for one product made in-house:

  1. Every incoming lot of each dietary ingredient: your identity examination or test, recorded.
  2. Every incoming lot of other components: check the CoA against your specification once the supplier is qualified; test yourself until then.
  3. Every batch: in-process weight checks, recorded in the batch record.
  4. Finished batches: the tests your specification calls for, on every batch until you have the data to justify a sampling plan.

The records that prove it

Subpart E ends with its own record list (111.95) [1]. For testing, keep:

  • your written specifications and the test or examination methods for each;
  • the result of each identity test or examination, by lot, with who did it and when;
  • each supplier qualification file and each periodic re-confirmation;
  • the documented basis for your finished batch tests and your sampling plan, with quality control's approval;
  • any 111.75(d) documentation;
  • every result that did not meet a specification and what you did about it. Under 111.77, a component that fails its identity specification must be rejected and not used; for most other specifications, quality control rejects the material unless it approves a treatment, in-process adjustment or reprocessing [1].

How long to keep these records is set in 111.605 and explained on records and reserve samples. Templates are on record templates.

Where your tests come from: the specification

Every test on this page answers a line in a specification. If you have not written them yet, start with writing specifications, then come back to identity testing for herbs for the test most small makers have to set up first.

References

  1. Electronic Code of Federal Regulations, 21 CFR Part 111 (sections 111.70, 111.77, 111.80 and 111.95 checked word for word), up to date as of August 13, 2026, read November 19, 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-B/part-111
  2. Legal Information Institute, Cornell Law School, 21 CFR 111.75, What must you do to determine whether specifications are met?, read November 19, 2026. https://www.law.cornell.edu/cfr/text/21/111.75
  3. U.S. Food and Drug Administration, Small Entity Compliance Guide: Current Good Manufacturing Practice in Manufacturing, Packaging, Labeling, or Holding Operations for Dietary Supplements, December 2010, read November 19, 2026. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/small-entity-compliance-guide-current-good-manufacturing-practice-manufacturing-packaging-labeling
  4. U.S. Food and Drug Administration, Current Good Manufacturing Practice in Manufacturing, Packaging, Labeling, or Holding Operations for Dietary Supplements, final rule, 72 FR 34752, June 25, 2007, preamble at 34836, read November 19, 2026. https://www.govinfo.gov/content/pkg/FR-2007-06-25/html/07-3039.htm