Buy a full case and the price per unit drops automaticallyRequest a sample
AccountCart0
All ContainersBottlesJarsCaps & ClosuresPumps & SprayersTubs & PailsJugsDroppersTinsTubesAccessoriesSeals & LinersCansBags & PouchesVialsLabels & DecorationBuckets & PailsDrumsBoxes & MailersBottling Tools
Industries
Learn

Do I need to test my supplement for bacteria, yeast and mold?

Updated

On this page7

Yes, in practice. Part 111 requires your component and finished product specifications to include limits on contamination that could adulterate the product, and microbes are one kind of contamination dried plant material carries. The rule does not give the numbers. USP's general chapter on microbiological attributes of supplements does, as recommended limits: in the edition read, dried or powdered botanicals up to 100,000 cfu/g total aerobic count and 1,000 cfu/g yeast and mold, with Salmonella and E. coli absent in 10 g. This page sets out USP's limits by product type, what each result means and what to do when one fails.

Why the answer is yes

Part 111 requires "limits on those types of contamination that may adulterate" in your component specifications and your finished product specifications (111.70) [1]. A dietary ingredient sold as a raw dried plant comes from a field, a drying shed and a warehouse, and it brings a microbial load with it. The way to show your limits are met is a count, either your own or a qualified supplier's certificate for components, and your own finished product results under your testing plan (what Part 111 requires you to test).

The same applies to every supplement form. Liquids and gummies, with water in them, also raise preservation questions specific to their form; dry capsules, tablets and powders rely mainly on clean ingredients and dry storage.

USP general chapter 2023, Microbiological Attributes of Nonsterile Nutritional and Dietary Supplements, as published in USP 38 to NF 33 (2015) [2]. The chapter heads these tables "Recommended Microbial Limit Requirements" and says they apply where an individual monograph does not set its own limits [2]. Units are colony-forming units (cfu) per gram or per mL.

Products and ingredients containing botanicals

MaterialTotal aerobic microbial countTotal combined yeasts and moldsBile-tolerant Gram-negative bacteriaSalmonella and E. coli
Dried or powdered botanicalsNot more than 10^5 (100,000)Not more than 10^3 (1,000)Not more than 10^3Absent in 10 g
Powdered botanical extractsNot more than 10^4 (10,000)Not more than 10^3Not set in this rowAbsent in 10 g
Tinctures; fluidextractsNot more than 10^4Not more than 10^3Not setNot set in this row
Infusions and decoctionsNot more than 10^2 (100)Not more than 10^1 (10)Not setNot set
Nutritional supplements containing botanicalsNot more than 10^4Not more than 10^3Not setAbsent in 10 g
Botanicals to be treated with boiling water before useNot more than 10^6Not more than 10^4Not more than 10^2Absent in 10 g

Products and ingredients without botanicals

MaterialTotal aerobic microbial countTotal combined yeasts and moldsE. coli
Other raw materials and dietary supplement ingredientsNot more than 10^3Not more than 10^2Absent in 10 g
Nutritional supplements with synthetic or highly refined ingredientsNot more than 10^3Not more than 10^2Absent in 10 g

Source: USP 2023, tables 2 and 3, USP 38 to NF 33 [2]. USP's current version of the chapter is behind a subscription, so current figures may differ; read it, or ask your lab which edition its limits come from, before you copy these into a specification. USP chapters are reference standards for a supplement unless its label claims USP conformity, which is explained on disintegration and USP standards.

Two things in these tables matter for a capsule or tablet maker. First, a finished herb capsule falls under "nutritional supplements containing botanicals," with a total aerobic limit ten times lower than the raw dried botanical row. A raw herb that just meets its own limit can push a finished product over. Second, extracts are expected to be cleaner than raw powders.

The tests behind the numbers

  • USP 2021, Microbial Enumeration Tests for nutritional and dietary supplements, is the counting method for total aerobic count and yeast and mold. USP 2022 refers to it for media, preparatory testing and sampling [3]. Its full text was not read for this page.
  • USP 2022, Microbiological Procedures for Absence of Specified Microorganisms, gives tests for the absence of Staphylococcus aureus, Salmonella species, Escherichia coli and Clostridium species, read in USP 35 to NF 30 (2012) [3]. The organisms to test for come from the monograph or from chapter 2023's guidance, and the chapter says manufacturers must also decide which other organisms are objectionable for their product [3].

When you order tests, name the chapter and organisms you want and ask the lab which edition it follows.

Reading a microbial result

What you seeWhat it meansWhat to do
Total aerobic count and yeast and mold well under your limits, specified organisms absentThe lot meets the microbial part of your specificationRecord and release, once the other specifications are met
Total aerobic count near your limit, lot after lotThe material or your process is running close to the lineTalk to the supplier about source and drying; tighten storage; consider more frequent testing
Total aerobic count above the limitThe lot does not meet its specificationHold; quality control rejects it unless it approves a treatment, in-process adjustment or reprocessing under 111.77 [1]
Yeast and mold above the limitMoisture at some stage: harvest, drying, storage or your roomReject or hold as above; check your storage humidity and container seals
E. coli or Salmonella detectedA specified organism is present where the specification requires absenceReject. If finished product has shipped, see recalls
A result reported as "within limits" with no numberYou cannot tell how close it wasAsk the lab or supplier for the count

Never blend a high-count lot with a clean one to bring the average down. Each lot has to meet its specification, and treatment of a lot that fails requires quality control approval under Part 111 [1].

Raw botanicals carry the most

USP's own tables show the order: raw dried botanicals are allowed the highest counts, extracts less, and refined or synthetic ingredients the least [2]. That follows from what each has been through. For a small maker, it means:

  • the herb is the ingredient to watch, and its certificate should show actual counts lot by lot;
  • herbs you grow or wildcraft have no supplier history at all, so test them (homegrown and wildcrafted herbs);
  • your own room, equipment and hands add to the count, which is why Part 111's hygiene rules matter (training and hygiene).

Dried herbs bought for tea come through the same supply chain; mold, pesticide residues and weed contamination in them are covered on contamination in herbal tea.

Sending samples to a lab that has tested your kind of material

Microbial methods for botanicals need a lab that has checked its method works with your kind of material. USP 2022 sends labs to preparatory testing before a method is used, which is how a lab shows its method recovers organisms from the material tested [3]; ask for that evidence. What to ask and what it costs are on choosing a lab.

References

  1. Electronic Code of Federal Regulations, 21 CFR Part 111, sections 111.70 and 111.77, up to date as of August 13, 2026, read November 19, 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-B/part-111
  2. United States Pharmacopeia, General Chapter 2023, Microbiological Attributes of Nonsterile Nutritional and Dietary Supplements, USP 38 to NF 33 (2015), tables 2 and 3, as reproduced by DrugFuture, read November 19, 2026. https://www.drugfuture.com/Pharmacopoeia/usp38/data/v38332/usp38nf33s2_c2023.html
  3. United States Pharmacopeia, General Chapter 2022, Microbiological Procedures for Absence of Specified Microorganisms: Nutritional and Dietary Supplements, USP 35 to NF 30 (2012), as reproduced by DrugFuture, read November 19, 2026. https://www.drugfuture.com/Pharmacopoeia/USP35/data/v35300/usp35nf30s0_c2022.html