How can one person be both the maker and the quality control?
Updated
On this page7
FDA allows it. Part 111 does not require a separate quality control person: in the 2007 rule's preamble FDA said the rule would not "preclude a person who performs 'Operation X' from being identified as the person who performs quality control operations for 'Operation X'" [1]. What the rule does require is that whoever is named for quality control have "distinct and separate responsibilities" when performing it, and FDA recommends a different person "whenever practical" [2]. One gap remains: the master record rule asks a second person to verify each manual weighing and addition, and no FDA text read for this page says how one person meets it. Below are the duties, FDA's words, that gap and your options.
What quality control has to do
Subpart F gives quality control a set of decisions that only it can make. Section 111.87: "Quality control personnel must conduct all required material reviews and make all required disposition decisions" [3]. The duties, grouped by when they come up [3]:
| When | Quality control duty | Section |
|---|---|---|
| Setting up | "Approving or rejecting all processes, specifications, written procedures, controls, tests, and examinations" | 111.105(a) |
| Setting up | Reviewing and approving the basis for qualifying any supplier | 111.105(b) |
| Setting up | Reviewing and approving each master manufacturing record and every change to it | 111.123(a)(1) |
| Setting up | Reviewing and approving calibration processes and periodically reviewing calibration records | 111.117 |
| Receiving | "Approving, and releasing from quarantine, all components, packaging, and labels before they are used" | 111.120(e) |
| Receiving | Reviewing and approving the results of required tests and examinations | 111.110(c) |
| During production | Determining whether in-process specifications are met; approving or rejecting any reprocessing | 111.123(a)(5), (6) |
| When something goes wrong | Conducting a material review and making a disposition decision when a specification is not met, a deviation or unanticipated occurrence happens, or calibration may have failed | 111.113 |
| Release | "Approving and releasing, or rejecting, each finished batch for distribution" | 111.123(a)(8) |
| Release | Approving for release, or rejecting, each packaged and labeled lot | 111.127(h) |
| After sale | Material review of returns; reviewing and approving decisions about complaint investigations | 111.130, 111.135 |
| Throughout | Ensuring reserve samples are collected and held | 111.105(g) |
Each of these is documented "at the time of performance," with the date and "Signature of the person performing the review, approval, or rejection" (111.140(b)(2)) [3]. Quality control also works from written procedures of its own (111.103) [3]. In February 2026 FDA cited a supplement maker under 111.103 after it found, in FDA's words to the firm, that "you were not able to provide written procedures for quality control operations" [4].
FDA's words on one person doing both
Three sources, all consistent, answer the question for most of the work.
The rule. Section 111.12(b): "You must identify who is responsible for your quality control operations" [3]. Part 111 defines quality control personnel as "any person, persons, or group, within or outside of your organization, who you designate to be responsible for your quality control operations" (111.3) [3]. Nothing in either says the person must be someone other than the maker.
The 2007 preamble. Responding to comment 221, FDA wrote [1]:
"Neither the definition of 'quality control personnel,' nor the requirements of final Sec. 111.12(b), would preclude a person who performs 'Operation X' from being identified as the person who performs quality control operations for 'Operation X.' However, we strongly recommend that the person you identify to perform a given quality control operation be a different person than the person who performed the operation that is subject to quality control oversight."
That passage appears at 72 FR 34867.
FDA's Small Entity Compliance Guide (December 2010). Question VI.7 asks: "May individuals who I identify to perform quality control operations also perform other functions, such as production functions?" The answer [2]:
"Yes. However, the DS CGMP rule requires that each person who is identified to perform quality control operations have distinct and separate responsibilities related to performing such operations from those responsibilities that the person otherwise has when not performing such operations (21 CFR 111.12(b)). We recommend that, whenever practical, the person performing a given quality control operation be a different person than the person who performed the operation subject to quality control oversight (72 FR 34752 at 34867)."
So the confirmed position is this: a sole proprietor may be named as quality control and may review their own work, provided the quality control responsibilities are written as distinct from production responsibilities and carried out as a separate act. A second person is FDA's recommendation, not a requirement.
The gap: verifying your own weighing
One requirement does not fit this answer. The master manufacturing record must include, "For manual operations," these actions (111.210(h)(3)(ii)) [3]:
- "One person weighing or measuring a component and another person verifying the weight or measure;"
- "One person adding the component and another person verifying the addition."
The batch record then needs the initials of the person who weighed and the person who verified, and of the person who added and the person who verified (111.260(j)(2)) [3]. This is a production verification step, written into the master record requirements in subpart H, separate from the quality control duties above.
In the 2007 preamble, FDA answered comment 261, which described bar code and scanning systems that let one person weigh and verify. FDA said "These comments describe a system partially under the control of automated equipment," that the requirement to verify the weight or addition of a component "can be achieved without requiring that one person do the weighing or measuring" and another check it, and that "The final rule makes clear that there must be a verification step and gives firms flexibility" [1]. That response is about automated systems.
Not confirmed: no FDA text read for this page (the rule, the 2007 preamble passages above, the compliance guide or the 2026 warning letters cited on these pages) says how a sole proprietor weighing by hand satisfies the second-person wording. Until FDA says otherwise, read the manual-operation text as written: a second person verifies. If your situation does not allow that, put the question to FDA in writing.
Your options
| Option | How it meets the rule | What it costs you | Fits |
|---|---|---|---|
| You are quality control, with written separation | Allowed for quality control duties per the preamble and the compliance guide [1][2] | Discipline: separate procedures, a separate review step and your signature in the quality control role | Most quality control duties for a sole maker |
| A trained second person for weighing and addition checks | Meets 111.210(h)(3)(ii) as written [3] | A part-time helper, family member or colleague trained and recorded under subpart B, present for each weighing | Manual weighing in every batch |
| An automated weigh-and-verify system | The approach FDA described in its response to comment 261 [1] | Equipment and software, which bring their own calibration and software backup records (111.35(b)) [3] | Higher volumes; confirm your setup with FDA before relying on it |
| An outside quality control reviewer | Quality control personnel may be "within or outside of your organization" (111.3) [3] | A consultant's fee per review; turnaround time before each release | Batch release and material reviews; adds the second set of eyes FDA recommends |
| A contract lab | Runs tests; quality control still reviews and approves results (111.110) [3] | Lab fees per test | Identity, contaminant and finished product testing; see choosing a lab |
| A contract manufacturer | Moves manufacturing, and its quality control, to the manufacturer's plant | You still owe your own duties as brand owner | When the record burden outweighs making it yourself; see what you owe when someone else makes it |
Several makers combine them: self-review for receiving and in-process checks, a helper for weighing days, and an outside reviewer for batch release.
Making the separation real when it is you
FDA's language asks for "distinct and separate responsibilities" [2]. The rule does not say how a single person shows that. These practices are one way to make it visible on paper; they are suggestions, not FDA requirements:
- Write two job descriptions. One procedure lists your production duties; another lists your quality control duties, citing the subpart F sections above. Name yourself in both, in writing, under 111.12(b).
- Separate the acts in time. Finish the batch and its record, then come back to it later as quality control, with a review checklist. Reviewing a record minutes after writing it invites seeing what you meant to write.
- Use a quality control checklist. Check each 111.260 entry against the master record and the specifications, line by line, and sign the checklist.
- Sign in the role. Sign quality control entries as quality control, with the date, as 111.140(b)(2) requires [3].
- Never release on a shortcut. If a specification was not met, open a material review and record the disposition (111.113), even when you are certain of the answer [3].
- Get an outside look periodically. Even if you do every routine review yourself, an outside reviewer looking at a sample of batch records each year gives you the "different person" FDA recommends for at least part of the work.
When to bring in a separate person
A second person becomes practical when volume, products or customers grow, or when a buyer or a third-party certifier asks for it. Moving quality control to someone else, and what changes when you hire, is on hiring help and a separate quality control person. If you are building your quality control procedures now, start from the review steps on the batch production record, and use the blank forms on Part 111 record templates.
Top picks
Top containers for capsules and tablets
300 cc · 45-400 · PET · Amber
500 cc · 53-400 · PET
200 cc · 38-400 · PET
120 cc · 38-400 · PET · Clear
120 cc · 38-400 · PET · Amber
300 cc · 45-400 · PET · Clear
120 cc · 38-400 · PET · Amber
175 cc · 38-400 · PET
References
- U.S. Food and Drug Administration, Current Good Manufacturing Practice in Manufacturing, Packaging, Labeling, or Holding Operations for Dietary Supplements, final rule, 72 FR 34752, June 25, 2007 (response to comment 221 at 72 FR 34867; response to comment 261 at 72 FR 34885 to 34886; both checked word for word on govinfo November 19, 2026). https://www.govinfo.gov/content/pkg/FR-2007-06-25/html/07-3039.htm
- U.S. Food and Drug Administration, Small Entity Compliance Guide: Current Good Manufacturing Practice in Manufacturing, Packaging, Labeling, or Holding Operations for Dietary Supplements, December 2010 (section VI, question 7), read November 19, 2026. https://www.fda.gov/regulatory-information/search-fda-guidance-documents/small-entity-compliance-guide-current-good-manufacturing-practice-manufacturing-packaging-labeling
- Electronic Code of Federal Regulations, 21 CFR Part 111, subpart F (sections 111.103 to 111.140) and sections 111.3, 111.12, 111.35, 111.87, 111.210 and 111.260, up to date as of August 13, 2026, read November 19, 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-B/part-111
- U.S. Food and Drug Administration, Warning Letter to Hearthy Foods, Inc., CMS 712415, February 10, 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/hearthy-foods-inc-712415-02102026