How do you measure your powder's bulk density?
Updated
On this page8
Weigh a known volume of powder poured loosely into a graduated cylinder, and divide the weight by the volume. That is the bulk density, in grams per milliliter. Tap the cylinder until the powder stops settling, read the new volume, and the same division gives the tapped density. The reference method is United States Pharmacopeia general chapter <616>, which uses about 100 g of powder in a 250 mL cylinder and a mechanical tapper [1]. A home version with a 100 mL cylinder and a 0.1 g scale gives a usable figure for choosing a capsule size. This page gives both, the two ratios that describe how a powder flows, and how to record the result.
Two densities, and why both matter
| Term | What it is | How it is measured | What it tells a capsule maker |
|---|---|---|---|
| Bulk density (also called poured or untapped density) | Mass of powder divided by its volume as poured, air spaces included | Pour without compacting, read the volume | What a loosely filled capsule holds |
| Tapped density | Mass divided by the volume after repeated tapping | Tap until the volume stops falling | Roughly how much a well-tamped capsule can hold |
A capsule filled on a manual machine sits between the two. Spreading powder into the bodies is close to pouring; each tamp pushes it toward the tapped density. That is why tamped capsules hold more than a fill weight worked from poured density predicts, and why the arithmetic on how much powder fits in a capsule is a starting point for weighing, never a substitute for it.
The pharmacopeial method
USP <616> has been harmonized with the European and Japanese pharmacopeias. The revised text posted by USP is marked "Stage 4 Harmonization / Official: August 1, 2025" [1]. The figures below come from that posted text. USP-NF itself is sold by subscription; if you work to it, check the official version in force when you test.
Bulk (untapped) density, Method 1
- If needed, pass the powder gently through a sieve with openings of at least 1.0 mm to break up clumps formed in storage, without changing the material [1].
- Weigh about 100 g, to 0.1 percent accuracy [1].
- Pour it without compacting into a dry 250 mL graduated cylinder readable to 2 mL. Level the surface gently if needed [1].
- Read the volume to the nearest graduation. This is V₀ [1].
- Bulk density = mass ÷ V₀, in g/mL [1].
If V₀ falls outside 150 to 250 mL, use a different mass and report it; for volumes of 50 to 100 mL, a 100 mL cylinder readable to 1 mL may be used [1].
Tapped density, Method 1
- Measure V₀ as above, then fix the cylinder in a tapping apparatus [1].
- The current text's high-drop method lifts and drops the cylinder "nominally 300 ± 15 taps from a height of 14 ± 2 mm" per minute; a low-drop method uses a fixed 3.0 ± 0.2 mm drop at about 250 taps per minute [1].
- Read the volume after 10, 500 and 1,250 taps [1].
- When successive readings differ by "less than or equal to 2 mL," take the last as the final tapped volume, V_F; otherwise keep tapping in further steps [1].
- Tapped density = mass ÷ V_F. Report the drop height used [1].
The home version
Without a mechanical tapper you cannot reproduce USP's tapped density exactly, but the poured density, which matters most for choosing a size, is easy to measure well.
You need: a 100 mL glass or plastic graduated cylinder with 1 mL marks (a kitchen measuring jug is too coarse), a scale reading to 0.1 g, a funnel, a sieve and a spoon.
- Sieve the powder gently to break up clumps.
- Tare the empty cylinder on the scale.
- Pour through the funnel until the powder reaches about the 80 to 100 mL mark. Do not tap, shake or press.
- Level the surface by tilting gently, without tapping, and read the volume at eye level.
- Weigh the filled cylinder. The reading is the powder's mass.
- Divide mass by volume. Example: 52.4 g in 87 mL gives 0.60 g/mL.
- Repeat twice with fresh powder and average the three results.
For an approximate tapped figure: after reading V₀, tap the cylinder base on a folded towel from the same small height, at a steady rate, counting 100 taps at a time and reading the volume after each 100. Stop when two readings in a row match. Record the number of taps and the drop height. Treat this as a home estimate, not a USP value.
Two ratios that describe flow
USP gives two ratios from the same two readings, under the heading "Measures of Powder Compressibility" [1]:
- Compressibility index (Carr's index) = 100 × (V₀ − V_F) ÷ V₀
- Hausner ratio = V₀ ÷ V_F
Both measure how much the powder settles. A powder that settles a lot under tapping is usually one that flows poorly, bridges over the holes in a capsule plate and fills unevenly. If your powder settles a great deal, expect to tamp more and to check weights more often, and see flow agents and fillers for the options. A worked example with the home figures: V₀ 87 mL, V_F 70 mL gives a compressibility index of 19.5 and a Hausner ratio of 1.24.
Why measure every lot
Density belongs to a particular lot of powder on a particular day. It changes with:
- The grind. Finer powders pack differently from coarser ones.
- The plant part and grade. Root and leaf of the same plant can differ widely.
- Moisture. Damp powder clumps and packs differently.
- Storage and handling. Powder settles in transit; a bag shaken on delivery reads differently from one that sat on a shelf.
So record density for each lot you receive, and re-measure when a fill weight drifts. No published table of densities for common herb powders was found in any pharmacopeial, academic or extension source read, and figures from one supplier's lot would not carry over to yours.
A record for each lot
| Field | Entry |
|---|---|
| Date | |
| Ingredient, plant part, supplier, lot | |
| Sieved? Sieve used | |
| Mass (g) | |
| V₀, poured volume (mL) | |
| Bulk density (g/mL), three readings and average | |
| V_F, tapped volume (mL), taps and drop height | |
| Tapped density (g/mL) | |
| Compressibility index and Hausner ratio | |
| Method (USP apparatus or home version) |
Put the number to work
With a measured density, the capsule fill weight calculator gives the theoretical fill per capsule for each size, and the worked examples and the reverse question, from an amount to a size, are on how much powder fits in a capsule. Tablet makers use the same density to set die fill; see setting tablet weight.
Top picks
Top containers for capsules and tablets
300 cc · 45-400 · PET · Amber
500 cc · 53-400 · PET
200 cc · 38-400 · PET
120 cc · 38-400 · PET · Clear
120 cc · 38-400 · PET · Amber
300 cc · 45-400 · PET · Clear
120 cc · 38-400 · PET · Amber
175 cc · 38-400 · PET
References
- United States Pharmacopeia, General Chapter 616, Bulk Density of Powders, Stage 4 harmonization text, official August 1, 2025 (copyright 2024), read November 19, 2026. https://usp.org/sites/default/files/usp/document/our-work/reference-standards/20240927HSm99375.pdf