What do I record for every batch?
Updated
On this page6
For every batch you record its batch number, the equipment used and when it was cleaned, the lot of every component and the weight used, who weighed and who checked, the results of every in-process check, the actual yield against the theoretical yield, the packaging and labeling done, and quality control's review and release decision [1]. That is the batch production record (BPR). Section 111.255 requires one "every time you manufacture a batch," and 111.260 lists fourteen kinds of entry [1]. The rule that trips makers is timing: most entries must be made at the time each step is performed. This page shows a completed example record in the order you fill it in.
The rule in brief
- "You must prepare a batch production record every time you manufacture a batch of a dietary supplement" (111.255(a)) [1].
- It "must include complete information relating to the production" and control of each batch (111.255(b)) [1].
- It "must accurately follow the appropriate master manufacturing record" (111.255(c)) [1]. In practice, you print or copy the MMR's steps into a blank BPR and fill in the results.
- Entries for manufacture, packaging, quality control review, material review and reprocessing must be documented "at the time of performance" (111.260(j) to (n)) [1]. Write each entry as the step happens, in ink or in a system that records when the entry was made. Records completed at the end of the day from memory do not meet that wording.
A batch, in Part 111's definition, is "a specific quantity of a dietary supplement that is uniform" and "produced during a specified time period according to a single manufacturing record" (111.3) [1].
A completed example record
The example follows the ginger rhizome capsule used on the master manufacturing record: 500 mg declared per capsule (an example input, not a recommendation), batch size 2,000 capsules, 100 per bottle. Names, numbers and times are illustrations. Each line shows the 111.260 paragraph it satisfies [1].
Header
| Entry | Example | 111.260 |
|---|---|---|
| Product and MMR reference | Ginger Root Capsules 500 mg (example), MMR-001 version 3 | 111.255(c) |
| Batch, lot or control number | G-261117-01 | (a) "The batch, lot, or control number" |
| Date started | 2026-11-17 | (j)(1) |
Before you start
| Entry | Example | 111.260 |
|---|---|---|
| Equipment and lines used | Manual capsule filler unit 1, plates 1 and 2; analytical balance B-1; bench scale B-2 | (b) "The identity of equipment and processing lines used in producing the batch" |
| Last cleaning of each | Filler and plates: 2026-11-16 15:20, AB. Balances: wiped 2026-11-17 08:00, AB | (c) "The date and time of the maintenance, cleaning, and sanitizing of the equipment" |
| Balance check | B-1 with 100 g reference: 100.001 g, pass | (g), with the calibration log on equipment cleaning and calibration |
Components
| Component | Your lot ID | Supplier lot | Weight or count used | Weighed by | Verified by | Added by | Verified by |
|---|---|---|---|---|---|---|---|
| Ginger rhizome powder | R-2611-04 | (supplier's) | 1,000.2 g | AB | CD | AB | CD |
| HPMC capsules, size 0 | R-2610-11 | (supplier's) | 2,040 shells issued | AB | CD | n/a | n/a |
Paragraph (d) requires "The unique identifier that you assigned to each component" (or packaging and label) used, and (e) "The identity and weight or measure of each component used" [1]. Paragraph (j)(2) requires the initials of the person who weighed each component, the person who verified the weight, the person who added it and the person who verified the addition [1]. The second set of initials is the hard part for a sole maker; it is discussed on quality control when you work alone.
During the batch
| Time | Step (from MMR) | Result | Initials |
|---|---|---|---|
| 09:05 | Step 6: fill plate 1 | Done | AB |
| 09:12 | Step 7: weigh 20 capsules, plate 1 | Net average 503 mg; range within IP-01 limits; pass | AB |
| 09:40 | Step 8: plate 2 sample | Net average 497 mg; pass | AB |
| ... | ... | ... | ... |
| 13:30 | Step 9: count | 1,955 good capsules; 45 rejected (32 under-filled, 13 split shells) | AB |
Paragraph (g) requires "The actual results obtained during any monitoring operation" and (h) the results of any test or examination performed during the batch [1]. Record the measured numbers; a tick mark proves nothing to a reviewer. How to take and judge fill weight samples is on fill weight checks during a batch.
Yield
| Entry | Example | 111.260 |
|---|---|---|
| Theoretical yield | 2,000 capsules (from the MMR) | |
| Actual yield | 1,955 capsules | (f) "A statement of the actual yield and a statement of the percentage of theoretical yield" |
| Percentage | 1,955 / 2,000 = 97.8 percent | (f) |
| Within MMR range? | Yes | If no, quality control reviews it |
Packaging and labeling
| Entry | Example |
|---|---|
| Bottles and closures used, with lot IDs | 19 bottles, lot R-2611-07; 19 caps, lot R-2611-08 |
| Count per bottle | 100 (checked by weight on 3 bottles) |
| Labels: issued, used, damaged and destroyed, returned | 22 issued; 19 applied; 1 damaged and destroyed; 2 returned to label stock; 22 = 19 + 1 + 2 |
| Label examined before use | Version 3, matches MMR representative label |
| Lot number and date applied | G-261117-01 printed on each label |
| Capsules bottled and left over | 19 × 100 = 1,900 bottled; 55 left over and destroyed, count and initials recorded; reserve samples taken from the 19 bottles |
Paragraph (k) requires documentation, at the time of performance, of packaging and labeling operations [1]. Subpart L adds that you "must control the issuance and use of packaging and labels" and examine them for each batch before use (111.410(b) and (c)) [1]. A label count that adds up (issued equals used plus destroyed plus returned) is a simple way to show that control; a count that does not add up means a label may be on the wrong product. Each lot of packaged product gets its batch, lot or control number (111.415(f)) [1], and that number is how a complaint or recall finds the batch later.
Quality control review and release
| Entry | Example | 111.260 |
|---|---|---|
| Finished product specification results | Fill weight, appearance, identity and lab results attached; all within spec | (i) documentation that the finished product meets specifications |
| Batch record reviewed, including monitoring and test results | Reviewed 2026-11-19 | (l)(1) |
| Reprocessing or repackaging | None | (l)(2) |
| Batch released or rejected | Released for distribution, 2026-11-19, signature | (l)(3) |
| Packaged and labeled product released or rejected | Released, 2026-11-19, signature | (l)(4) |
| Material review and disposition, if any | Not required | (m) |
| Reprocessing, if any | None | (n) |
Quality control must document these "at the time of performance," with the date and the signature of the person who performed the review (111.140(b)(2)) [1]. Until that signature is on the record, the batch is on hold.
Making the numbers reconcile
Every count in the record should add up: capsules made equals capsules bottled plus capsules set aside plus capsules destroyed; labels issued equals labels applied plus labels destroyed plus labels returned. In the example, 1,955 good capsules became 19 bottles of 100 (1,900), with 55 left over and accounted for. The theoretical 20 bottles became 19 because the actual yield was 97.8 percent, which in this example falls inside the yield range set in the MMR. Reserve samples are pulled from the packaged lot, in the same container you sell in; how many and for how long is on records and reserve samples.
When a number does not reconcile, or an in-process check fails, the batch goes to quality control for a material review and disposition decision (111.113) [1], documented in the BPR at the time it happens (111.260(m)) [1]. Checks like these are the reason the record exists.
Mistakes FDA has cited
In 2026 letters FDA cited firms that prepared no batch records at all, and firms whose records lacked the identity of equipment, the cleaning and maintenance dates, yield statements, the actual results of monitoring, evidence that specifications were met, and packaging quantities [2][3]. Each is a row in the example above. The full table of findings is on what FDA cites at small supplement makers.
How long you keep it
The BPR is kept for the period in subpart P, measured from the shelf-life date if you use one or from distribution of the last bottle of the batch. The figures, and how they apply to reserve samples taken from the same batch, live on records and reserve samples. A blank BPR is on Part 111 record templates.
Top picks
Top containers for capsules and tablets
300 cc · 45-400 · PET · Amber
500 cc · 53-400 · PET
200 cc · 38-400 · PET
120 cc · 38-400 · PET · Clear
120 cc · 38-400 · PET · Amber
300 cc · 45-400 · PET · Clear
120 cc · 38-400 · PET · Amber
175 cc · 38-400 · PET
References
- Electronic Code of Federal Regulations, 21 CFR Part 111, subpart I (sections 111.255 and 111.260) and sections 111.3, 111.113, 111.140, 111.410 and 111.415, up to date as of August 13, 2026, read November 19, 2026. https://www.ecfr.gov/current/title-21/chapter-I/subchapter-B/part-111
- U.S. Food and Drug Administration, Warning Letter to Nature's Elements, Inc., CMS 719302, April 7, 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/natures-elements-inc-719302-04072026
- U.S. Food and Drug Administration, Warning Letter to Nutratech, LLC, CMS 723021, June 4, 2026. https://www.fda.gov/inspections-compliance-enforcement-and-criminal-investigations/warning-letters/nutratech-llc-723021-06042026