How do I clean, calibrate and keep records for my equipment?
Updated
On this page8
Write a cleaning procedure for each piece of equipment and follow it between every product and batch, calibrate every scale and instrument before first use and on a written schedule, and record both in a log for each piece of equipment [1]. Section 111.25 of Part 111 asks for the written procedures, 111.27 sets what equipment must be and do, and 111.35 lists the records [1]. FDA's 2026 letters cite residue in hopper seams, compacted powder in a blender and records that call equipment clean without showing how [2][3]. This page gives the procedure for cleaning between products, the calibration schedule and the log.
What the rule asks
| Requirement | Section [1] | Quoted |
|---|---|---|
| Written procedures for calibration | 111.25(a) | "Calibrating instruments and controls that you use in manufacturing or testing a component or dietary supplement" |
| Written procedures for automated equipment | 111.25(b) | "Calibrating, inspecting, and checking automated, mechanical, and electronic equipment" |
| Written procedures for cleaning | 111.25(c) | "Maintaining, cleaning, and sanitizing, as necessary, all equipment, utensils, and any other contact surfaces" |
| Suitable equipment | 111.27(a) | "You must use equipment and utensils that are of appropriate design, construction, and workmanship" |
| Calibration | 111.27(b) | "You must calibrate instruments and controls you use in manufacturing or testing a component or dietary supplement" |
| Equipment logs | 111.35(b)(2) | "Documentation, in individual equipment logs, of the date of the use, maintenance, cleaning" and sanitizing |
| Calibration records | 111.35(b)(3) | "Documentation of any calibration, each time the calibration is performed" |
Your batch production record also carries cleaning: 111.260(c) requires "The date and time of the maintenance, cleaning, and sanitizing of the equipment and processing lines" used for each batch [1]. Quality control reviews and approves the calibration processes and periodically reviews calibration records (111.117) [1].
Equipment that can be cleaned
Before writing a cleaning procedure, check that the equipment allows one. Section 111.27(a)(2) asks for equipment designed and used so that its use "will not result" in contamination of product [1]. In a May 2026 letter FDA cited 111.27(a)(4) at a supplement maker: "You failed to ensure equipment and utensils you use have seams that are smoothly bonded," after finding residue in a hopper's seams after cleaning, on equipment shared with a product containing wheat bran [2]. When you buy a capsule filler, tablet press, blender or scoop, look for:
- surfaces you can reach with a brush and see when dry;
- parts that come apart without tools, or with simple ones;
- smooth welds and seams with no crevices that trap powder;
- materials that tolerate your cleaning agent and sanitizer.
Manual plate fillers are mostly flat plates and pins, which are easy to clean. The next step up is on equipment for the next step.
A changeover cleaning procedure
Every maker's equipment differs, so treat this as the shape of a procedure and adapt each step to your own machine. Write yours for each machine, test it, and keep the version number on the log.
- Clear the line. Remove every component, in-process container, finished product, label and document from the previous batch. Nothing from it stays on or near the bench.
- Dismantle. Take the equipment apart to the point named in your procedure for that machine.
- Dry clean first. Vacuum loose powder before any water touches it, so powder does not turn to paste in seams. Use a vacuum with a filter suited to fine dust, and keep a brush for loosening powder from seams the vacuum nozzle cannot reach, with the vacuum running beside it, as the dust precautions on working with powder dust set out.
- Wash. Wash parts with the cleaning agent your procedure names, at the dilution the agent's maker states, paying attention to seams, pin holes and corners.
- Rinse. Rinse until no cleaning agent remains.
- Sanitize where needed. Part 111 defines sanitize as "to adequately treat cleaned equipment, containers, utensils, or any other cleaned contact surface" so as to reduce microorganisms (111.3) and asks for it "as necessary" [1]. Your procedure says when: always for products that can support microbial growth, and per your own judgment for dry products.
- Dry fully. Air-dry or wipe with lint-free cloths. Moisture left on a capsule plate or press tooling can cause sticking and microbial growth.
- Inspect. Look at every part under good light. Residue in a seam or pin hole means the clean failed; repeat it.
- Reassemble and tag. Reassemble, and tag or record the equipment as clean, with the date, time and your initials.
- Log it. Enter the cleaning in the equipment log and, when the next batch starts, in its batch record.
A cleaning procedure is only as good as its evidence. In a June 2026 letter FDA noted that a firm's batch records carried only general statements that equipment was clean, and said it could not evaluate the firm's corrective actions because no supporting evidence, such as swab results, logs or calibration records, was submitted [3]. You do not have to run swab tests to comply, but your log should say what was cleaned, how, by whom and when, and what you saw at inspection.
Cross-contact and allergens between products
When two products share equipment, residue from one can carry into the next. For a maker of one product, that risk is small. For a maker with several products, especially one that contains a major food allergen, it decides your schedule:
- Run allergen-containing products last before a full clean, so residue is not carried into products without them.
- Clean fully between products, not only between batches of the same product. Part 111 asks for "Separating the manufacturing, packaging, labeling, and holding of different product types" (111.20(c)(3)) [1].
- Consider dedicated small parts (scoops, funnels, capsule plates) for an allergen product, labeled as such.
- Label what is actually in the bottle. An undeclared allergen is a labeling violation of its own; FDA cited it in the same June 2026 letter [3]. Allergen labeling for supplements, including sesame, is on allergens on supplement labels.
Calibration
Section 111.27(b) requires calibration of instruments and controls used in manufacturing or testing, "Before first use" and then either "At the frequency specified in writing by the manufacturer of the instrument and control" or "At routine intervals or as otherwise necessary to ensure the accuracy and precision of the instrument and control" (111.27(b)(1) to (3)) [1]. Where the instrument maker gives no written frequency, your own procedure sets the routine interval. Instruments a small maker typically has:
| Instrument | What it is used for | What to record each time |
|---|---|---|
| Analytical or precision balance | Weighing components, capsule and tablet fill checks | Reference weights used, readings, pass or fail against your tolerance, date, initials |
| Bench or floor scale | Weighing bulk components, batch charges | Same |
| Thermometer or data logger | Storage temperature | Comparison against a reference thermometer, date, initials |
| Hygrometer | Room or storage humidity | Comparison against a reference, date, initials |
| Tablet hardness tester or moisture analyzer, if you have one | In-process and finished checks | Per the instrument maker's calibration method |
Two levels of calibration work for most small makers. A full calibration, by a calibration service or by you with certified reference weights, at the frequency the instrument maker specifies. And a quick check before each use, placing one or two reference weights on the balance and recording the reading. The rule names the first; the second is a practice that catches a balance that has drifted before it costs you a batch. The fill weight checks that depend on your balance are on fill weight checks during a batch.
If a calibration fails, stop using the instrument, and treat any batch weighed on it since the last good calibration as a question for quality control. Part 111 requires a material review when there is reason to believe calibration problems affected a batch (111.113(a)) [1]; how that works for one person is on quality control when you work alone.
The equipment log
Section 111.35(b) asks for individual equipment logs and calibration records [1]. One log per piece of equipment, kept near it, with a line for each event. An example, with illustrative entries:
| Date and time | Event | Detail | Product or batch | Initials |
|---|---|---|---|---|
| 2026-11-17 08:10 | Balance check | 100.000 g reference read 100.001 g; within tolerance | n/a | AB |
| 2026-11-17 08:20 | Use | Filling | Batch G-261117-01 | AB |
| 2026-11-17 14:45 | Cleaning | Changeover clean, SOP-05 v2; dry vacuum, wash, rinse, air dry; inspected, no residue | After G-261117-01 | AB |
| 2026-11-18 09:00 | Maintenance | Replaced worn pin on plate 2 | n/a | AB |
Automated or electronic equipment adds two records: calibrations, inspections and checks (111.35(b)(4)) and "Backup file(s) of current software programs" where software controls the equipment (111.35(b)(5)) [1]. Blank forms are on Part 111 record templates. How long to keep the logs is on records and reserve samples.
Where the cleaning record goes next
Each batch record names the equipment used and when it was last cleaned, so a clean that is logged here is checked again when quality control reviews the batch. That record is on the batch production record.
Top picks
Top containers for capsules and tablets
300 cc · 45-400 · PET · Amber
500 cc · 53-400 · PET
200 cc · 38-400 · PET
120 cc · 38-400 · PET · Clear
120 cc · 38-400 · PET · Amber
300 cc · 45-400 · PET · Clear
120 cc · 38-400 · PET · Amber
175 cc · 38-400 · PET