Buy a full case and the price per unit drops automaticallyRequest a sample
AccountCart0
All ContainersBottlesJarsCaps & ClosuresPumps & SprayersTubs & PailsJugsDroppersTinsTubesAccessories
Industries
Learn
What goes wrong

The pH moved after filling

Updated

On this page5

The batch measured correctly, the jars were filled, and six weeks later the pH is somewhere else. On its own that is a curiosity. Given what pH controls, it is a preservation failure waiting to be discovered.

Why it matters more here than elsewhere

pH decides whether the preservative is in its active form. A drift of half a point can take a working preservation system outside its range without changing anything a customer could see.

It also affects the actives. L-ascorbic acid, for instance, degrades above roughly pH 3.5, so upward drift in a vitamin C product destroys the thing being sold.

What moves it

Ingredients continuing to react after manufacture, particularly where something was added warm. Carbon dioxide exchange in a package that is not a good barrier. Interaction with the container itself, which is why packaging compatibility is part of a stability study rather than an afterthought. And degradation products: L-ascorbic acid breaking down yields threonic and oxalic acid, which are acids, and they move the pH as they accumulate.

That last one is worth sitting with: the active degrading changes the conditions that were protecting it, which accelerates the degradation.

Measuring it properly

At a defined temperature, on the finished product rather than the water phase, with a meter rather than strips. Record it at manufacture and again at each stability timepoint, because pH is one of the attributes a stability study tracks precisely because it moves early.

A drift visible at four weeks accelerated is a drift that will happen in real time.

Specifying a range

Write the specification as a range you can hold and that the preservative tolerates throughout, not as a single number you hit on the day.

Then treat a batch outside the range as a batch to investigate rather than to adjust and ship. An out-of-range pH is the symptom; the cause is usually a raw material lot, a process change or a package interaction, and adjusting it back hides the cause without removing it.

References

Literature on L-ascorbic acid stability: optimum around pH 2.5–3.0, degrading in oxygen, light and heat and above roughly pH 3.5, catalyzed by Cu(II) and Fe(III). ncbi.nlm.nih.gov
Written from published standards and peer-reviewed work, not from a laboratory of our own. Your own challenge and stability results, your supplier's specifications and a qualified safety assessment override anything general said here. Nothing on this site is a safety substantiation.