How do I measure water activity in a small gummy operation?
Updated
On this page9
You measure water activity with a benchtop meter that seals a sample in a small chamber and reads the humidity of the air above it once the two reach balance, or you send pieces to a lab that does the same. The reference methods are USP general chapter <922> Water Activity and AOAC Official Method 978.18, a chilled mirror method that a 2024 review reports is named in USP's multivitamin chewable gel monograph. For a gummy, the details that decide whether the number is right are a sealed sample prepared the same way every time, a steady temperature and a meter checked against saturated salt standards. This page sets out the steps, the calibration and how often to measure.
The methods behind the number
| Method | What it is | Status, as read |
|---|---|---|
| USP general chapter <922> Water Activity | Outlines "the recommended methods to qualify, calibrate, and use water activity meters," as USP's scientist described it [1] | Official May 1, 2021 [2]; the official text is sold by subscription and was not read |
| AOAC Official Method 978.18 | A chilled mirror dew point method [2] | Named with the limit in USP's multivitamin chewable gel monograph [2]; the AOAC text itself is sold by subscription and was not read |
| USP general chapter <1112> | Application of water activity determination to nonsterile products; recommends AOAC 978.18 [2] | Not read |
All of them rest on the same principle: "Measurements of aw are made by allowing a sample to equilibrate with the moisture in the headspace" [2]. Once the sample and the air in the sealed cup are in balance, the relative humidity of that air, divided by 100, is the sample's water activity.
The instruments
Water activity meters use several sensing principles. The two a small operation is most likely to meet:
| Type | How it reads | Accuracy as reported in 2009 [3] |
|---|---|---|
| Chilled mirror dew point | Cools a mirror until dew forms and reads the dew point | ±0.003 aw, in under 5 minutes |
| Capacitance | A polymer film between two plates changes with humidity | ±0.015 aw across the range, "calibrated against known saturated salt standards" |
The 2009 Food Technology article that gives those figures also says chilled mirror instruments work "without the need for calibration" [3]. USP's chapter covers qualifying and calibrating every meter [1], and Cundell notes that water activity meters "can be calibrated and qualified using saturated salt reference solutions" [2]. This page follows USP: calibrate and check whatever meter you use, and keep the records; the shared calibration rules are on cleaning and calibration.
Accuracy matters most near your limit. For example, with a specification of 0.70, a reading of 0.69 from a meter good to ±0.015 does not clearly pass.
Calibrating and checking the meter
A saturated salt solution holds the air above it at a fixed relative humidity for a given temperature, which makes it a reference standard for a water activity meter. The National Bureau of Standards (now NIST) measured these fixed points in a 1977 paper that remains the usual reference; its values at 25°C (77°F), converted from percent relative humidity to water activity, include [4]:
| Saturated salt solution | aw at 25°C |
|---|---|
| Sodium chloride | 0.753 ± 0.001 |
| Magnesium nitrate | 0.529 ± 0.002 |
| Potassium carbonate | 0.432 ± 0.004 |
| Magnesium chloride | 0.328 ± 0.002 |
Pick standards that bracket your gummy's range. Sodium chloride at 0.753 sits almost on the 0.75 that USP's slides recommend for chewable gels, and magnesium nitrate near the low end of the range a 2024 review gives for gummies [2]. Check the meter at the temperature you measure at, since these values shift with temperature. How often to calibrate and what counts as a passing check are set in USP's chapter and in your instrument maker's instructions; follow them and write the frequency and the acceptance criterion into your procedure. Whatever standards you use, prepared or bought ready-made, record their lot and expiry.
Measuring a gummy, step by step
- Check the meter with a standard near your specification limit, at the temperature you will measure at. Record the result. If it fails, stop and recalibrate.
- Take the sample. Pull pieces according to your plan (for a batch, from the start, middle and end of the deposit). Keep them in a sealed, water-tight container with little air space until you measure, and measure soon after opening, since a gummy starts trading water with the room as soon as it is exposed [2].
- Prepare it the same way every time. A gummy can be drier on the surface than inside. AquaLab, a meter maker, warns that over-drying the outside causes "case-hardening that traps water inside" [5]. Cutting pieces into a few parts exposes the interior and gives a reading for the whole piece; whole pieces give a reading closer to the surface. Choose one method, write it into your procedure and never mix them. Follow the instrument's instructions for filling the sample cup.
- Hold the temperature steady. Water activity changes with temperature. Bring samples to the instrument's temperature before measuring, and record the temperature with the result.
- Read at equilibrium. Let the instrument decide when the reading is stable, and do not open the chamber early.
- Repeat. Measure more than one sample per pull and record each reading, so you can see the spread as well as the average.
- Record and compare with your specification. A failing reading is an out-of-specification result, handled through quality control.
How often to measure
| Point | Why | What you do with the number |
|---|---|---|
| During curing, at set intervals | Tracks drying until readings stop falling | Builds your curing curve (curing gummies) |
| At the end of curing, before packing | Confirms the batch reached its target | In-process check (in-process checks for a gummy batch) |
| At release | Part of the finished product specification | Release decision (testing a gummy batch) |
| At each stability pull | Shows drift in the package | Supports the shelf life (how long gummies last) |
| After a complaint of sweating, sticking or hardening | Separates a packaging or storage problem from a batch problem | Investigation (gummies that sweat or stick together) |
Sending samples to a lab instead
If you do not own a meter, a lab can measure water activity for you. Laboratories that test foods list the method by name; a state public health laboratory in Texas, for example, lists water activity by "AOAC 978.18" for food products [6]. When you choose a lab:
- Ask which method and instrument it uses, and at what temperature it reports.
- Ask how it prepares a gummy (whole or cut). Tell it which you use in house if you want results you can compare.
- Ship in sealed, water-tight containers with little air space, and note when the pieces were packed. A gummy that gains or loses water in transit gives a reading for the trip.
- Ask for the result with the temperature and the calibration check on the report.
Choosing and qualifying a lab is a shared subject, on choosing a lab. A lab works for release and stability samples; curing decisions need readings within hours, which a meter in house gives you.
What to write down
Each reading needs the batch number, the sample point, the preparation method, the temperature, the reading, the meter's identity and the result of that day's check. Ready-made tables for the water activity log and the curing room log are on gummy batch record templates.
From measuring to curing
With a reliable reading, you can set curing conditions from your own data rather than from someone else's figure. That method is on curing gummies.
Top picks
Top containers for gummies and chews
500 cc · 53-400 · PET
120 cc · 38-400 · PET · Clear
120 cc · 38-400 · PET · Amber
120 cc · 38-400 · PET · Amber
200 cc · 38-400 · PET
300 cc · 45-400 · PET · Amber
300 cc · 45-400 · PET · Clear
175 cc · 38-400 · PET
References
- Natalia Davydova, United States Pharmacopeia, slides presented at the FDA and M-CERSI workshop on candy-like products, October 30, 2023 (slides, not the monographs), read November 19, 2026. https://cersi.umd.edu/sites/cersi.umd.edu/files/Session_1-1_NataliaDavydovaCandy-Like_Oct30_2023.pdf
- Tony Cundell, American Pharmaceutical Review 27(5), Microbiological Attributes of Chewable Gels (Gummies), July/August 2024, pp. 8 to 12, read November 19, 2026. https://www.americanpharmaceuticalreview.com/Featured-Articles/614408-Microbiological-Attributes-of-Chewable-Gels-Gummies/
- Neil Mermelstein, Institute of Food Technologists, Food Technology Magazine, Measuring Moisture Content and Water Activity, November 1, 2009, read November 19, 2026. https://www.ift.org/food-technology-magazine/measuring-moisture-content-water-activity
- Lewis Greenspan, National Bureau of Standards, Humidity Fixed Points of Binary Saturated Aqueous Solutions, Journal of Research of the National Bureau of Standards, Section A, 81A(1):89 to 96, January to February 1977, table 2, read November 19, 2026. https://nvlpubs.nist.gov/nistpubs/jres/81A/jresv81An1p89_A1b.pdf
- AQUALAB (instrument maker), Solving the water problem in gummies, undated, read November 19, 2026. https://aqualab.com/learn/solving-the-water-problem-in-gummies
- Texas Department of State Health Services, Laboratory Services, Water Activity, AOAC method 978.18, undated, read November 19, 2026. https://www.dshs.texas.gov/water-activity-aoac-method-978-18