How do I test the pH of a pickle or a ferment?

Updated

On this page7

For a finished jar, test the equilibrium pH: wait at least a day after processing, drain the jar, blend the solids and liquid back together in their original proportions, and read the slurry at room temperature with a freshly calibrated meter, taking two or three readings that agree. For a ferment still in the crock, test the brine instead, because the vegetables do little to change it, taking two or three readings each time, daily for the first several days, until the pH has dropped below 4.6 and kept falling toward 4.1. Record every reading. A reading close to the line has to be read against your meter's accuracy, and this page shows how.

Before you sample

  • Calibrate first, at pH 7 and 4, the same day and just before testing [1][2]. The routine is on Calibrating and caring for a pH meter.
  • Bring the sample to room temperature. Oklahoma State's food processing center says samples should be at a constant temperature, preferably room temperature [1].
  • Have distilled or deionized water ready for rinsing the probe and for thinning the blend [1].

Testing a finished jar

The number you want from a canned or refrigerated jar is its equilibrium pH: the pH once acid has moved all the way into the vegetables. Why that takes time, and why 4.6 is the line, is explained on Equilibrium pH and the 4.6 line.

  1. Wait. Oregon State Extension says to wait at least 24 hours after processing so the product reaches equilibrium [3]. The Nevada Department of Agriculture says to test once the jar has cooled, usually 12 to 24 hours after processing [2]. Waiting the full 24 hours satisfies both.
  2. Pick the jar. Nevada says, "You should sample each batch" [2]. Choose a jar from the batch as packed, not one you topped up or packed differently.
  3. Drain. Oklahoma State's method for pieces in liquid, such as pickles or chunky salsa: drain the contents for two minutes on a U.S. standard No. 8 sieve tilted at 17 to 20 degrees, and keep the liquid [1]. At home, a coarse strainer propped at a slight angle over a bowl does the same job.
  4. Blend. For equilibrium pH, blend the solids and the liquid back together in their original ratio, or blend the whole contents of the jar [1]. If the blend is too thick to read, add distilled water, up to 20 parts water per 100 parts sample [1]. Nevada notes that added distilled water does not change the pH [2].
  5. Deal with oil if there is any. Skim or pour it off; if it will not separate, chill or freeze and thaw the sample, remove the oil, and let the sample return to room temperature before testing [1].
  6. Read. Rinse the probe with distilled water and blot it dry. Immerse the tip and give it at least one minute to settle before you record [1].
  7. Repeat. Test a fresh portion of the same blend. Oklahoma State says the two readings should agree within the meter's accuracy limits [1]; Oregon State's demonstration takes three readings and records the average [3].

Oklahoma State also describes testing the drained liquid and the rinsed, blended solids separately [1]. That can show you whether a dense vegetable is lagging behind its brine. For a pass or fail against 4.6, use the blended equilibrium reading.

Testing a ferment in the crock

During fermentation the useful number is the brine pH. Snyder, Breidt, Andress and Ingham, in their best-practice paper for small fermented-vegetable businesses, explain that "because the vegetables used for fermentation typically exhibit little buffering capacity, pH may be monitored in the brine" [4].

How to draw the sample

Take brine from within the ferment, below the surface, with a clean spoon, ladle or syringe, and test it in a cup. Snyder and colleagues say samples "must be representative of the whole, and generally two or three distinct measurements are taken at each time point" [4]. Testing in a cup keeps the probe out of the crock and lets you rinse it properly between readings. Discard the tested brine rather than pouring it back.

How often

Product and methodScheduleTargetSource
Vegetable ferments in generalDaily for the first several days, then less oftenA steady decline to below 4.6, usually within a weekSnyder et al., 2020 [4]
Kimchi at about 68 to 72°F (about 20°C)Every 12 hours, for up to 2 daysBelow 4.6Snyder et al., 2020, Table 1 [4]
Kimchi below 41°F (5°C), fermented 3 to 4 daysEvery day, for 4 daysBelow 4.6Snyder et al., 2020, Table 1 [4]
Ferments sold at a farmers marketContinue until finished4.1 or below; at 4.2 to 4.6 the product must be kept refrigeratedVirginia Cooperative Extension FST-308NP, 2019 [5]

Snyder and colleagues write that "effectively managed vegetable fermentation systems typically expect to reach a pH of < 4.6 within a week," though some vegetables and cooler temperatures take longer [4]. Kimchi timing in full is on How long to ferment kimchi.

Keep testing after the bubbles stop

Two instructions from the same paper matter more than any single reading. A ferment whose pH does not keep falling is a failed ferment: "products in which a continued pH decline is not recorded, should be discarded" [4]. And brine pH "should also be monitored after evident microbial activity has ceased," to show that it is not climbing back up [4]. A rising pH in a finished ferment is a sign of spoilage, often from surface yeast; see Kahm yeast or mold?.

Recording what you measured

Oklahoma State says to record readings to the nearest 0.05 unit, or 0.1 if that is your meter's resolution, and notes that federal reporting generally uses the nearest tenth [1]. Snyder and colleagues list date, time and pH for each sample as the minimum [4]. A workable row in a log looks like this:

DateTimeBatch or crockSample (brine or blend)ReadingsAverageTemp of room or crockInitials
Oct 38:00 amKraut crock 2Brine4.42, 4.45, 4.404.4268°FJD

Write down the calibration check alongside it. The Batch and fermentation log has these columns ready, and how long sellers must keep these records is on Record keeping as you grow.

What a reading near the line means

Every meter has a stated accuracy, and the true pH can sit anywhere inside that band around the number on the screen. Oklahoma State notes that some inexpensive meters are accurate only to plus or minus 0.2 units, which matters near 4.6 [1].

Meter showsTrue pH could be, with ±0.1 accuracyTrue pH could be, with ±0.2 accuracyWhat it tells you
4.03.9 to 4.13.8 to 4.2Comfortably below 4.6 either way
4.24.1 to 4.34.0 to 4.4Below 4.6; a ferment here is not yet at the 4.1 finish
4.44.3 to 4.54.2 to 4.6With a ±0.2 meter, the reading cannot rule out 4.6
4.54.4 to 4.64.3 to 4.7Too close to call with either meter
4.6 or above4.5 or higher4.4 or higherNot acidic enough

How to act on it depends on what you are testing.

  • A ferment still in progress: keep fermenting and keep testing on the schedule above. A reading of 4.4 on day three is normal progress, as long as the next reading is lower.
  • A ferment that has stopped falling above 4.6: Snyder and colleagues say to discard it [4].
  • A canned jar from a tested home recipe that reads near or above 4.6: recalibrate, check against pH 4 buffer, and retest a fresh blend. If the reading holds, do not eat the batch or store it on the shelf, and ask your county extension office to help you find what went wrong. A tested recipe followed exactly should not read there, so something in the ingredients or method changed.
  • A product you sell: a reading inside your meter's accuracy band of 4.6 is not a pass. Your process authority sets the target pH for your product and the margin you work to; the process authority page explains that review.

Turning a reading into a decision

If you have a number and want a quick read on what it means for a vinegar pickle, a ferment or a refrigerated product, enter it with your meter's accuracy in the pH reading checker. For the ferment finish line itself, and the signs that go with it, see How you know a ferment is done.

References

  1. McGlynn, W., Choosing and Using a pH Meter for Food Products, Oklahoma State University FAPC-117, July 2016. https://extension.okstate.edu/fact-sheets/choosing-and-using-a-ph-meter-for-food-products.html
  2. Nevada Department of Agriculture, Purchasing and using a pH meter (Measuring pH, undated). https://agri.nv.gov/uploadedFiles/agrinvgov/Content/Food/Craft_Foods/Measuring_pH_.pdf
  3. Street, K., pH meter calibrating and testing for pickled food products, Oregon State University Extension Service, December 2022. https://extension.oregonstate.edu/es/node/198996/printable/print
  4. Snyder, A., Breidt, F., Andress, E. L., and Ingham, B. H., Manufacture of Traditionally Fermented Vegetable Products: Best Practice for Small Businesses and Retail Food Establishments, Food Protection Trends 40(4):251-263, 2020. https://www.ars.usda.gov/ARSUserFiles/60702500/Fermented%20Veg%20Manuscripts/p437.pdf
  5. Virginia Cooperative Extension, What do I need to know to sell Fermented Vegetables at the farmers market?, FST-308NP, 2019. https://ps.spes.vt.edu/producers/documents/FST-308.pdf